JACC. Cardiovascular interventions · 2021

The Use and Outcomes of Cerebral Protection Devices for Patients Undergoing Transfemoral Transcatheter Aortic Valve Replacement in Clinical Practice.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Stachon Peter, Kaier Klaus, Heidt Timo, Wolf Dennis, Duerschmied Daniel, Staudacher Dawid, Zehender Manfred, Bode Christoph, von Zur Mühlen Constantin

Аннотация

OBJECTIVES: This study hypothesized that cerebral protection prevents strokes in patients undergoing transfemoral transcatheter aortic valve replacement (TAVR) in clinical practice.

BACKGROUND: Preventing strokes is an important aim in TAVR procedures. Embolic protection devices may protect against cardiac embolism during TAVR, but their use and outcomes in clinical practice remain controversial.

METHODS: Isolated transfemoral TAVR procedures performed in Germany with or without cerebral protection devices were extracted from a comprehensive nationwide billing dataset.

RESULTS: A total of 41,654 TAVR procedures performed between 2015 and 2017 were analyzed. The overall share of procedures incorporating cerebral protection devices was 3.8%. Patients receiving cerebral protection devices were at increased operative risk (European System for Cardiac Operative Risk Evaluation score 13.8 vs. 14.7; p < 0.001) but of lower age (81.1 vs. 80.6 years; p = 0.001). To compare outcomes that may be related to the use of cerebral protection devices, a propensity score comparison was performed. The use of a cerebral protection device did not reduce the risk for stroke (adjusted risk difference [aRD]: +0.88%; 95% confidence interval [CI]: -0.07% to 1.83%; p = 0.069) or the risk for developing delirium (aRD: +1.31%; 95% CI: -0.28% to 2.89%; p = 0.106) as a sign of acute brain failure. Although brain damage could not be prevented, in-hospital mortality was lower in the group receiving a cerebral protection device (aRD: -0.76%; 95% CI: -1.46% to -0.06%; p = 0.034).

CONCLUSIONS: In this large national database, cerebral embolic protection devices were infrequently used during TAVR procedures. Device use was associated with lower mortality but not a reduction in stroke or delirium. Future studies are needed to confirm these findings.