Dose Distribution Degradation of Carbon-ion Radiotherapy Caused by Tumor Cell-specific Relative Biological Effectiveness of Osteosarcoma: A Simulation Study Using In Vitro Experimental Results.
Аннотация
BACKGROUND/AIM: Dose distributions of carbon-ion radiotherapy (C-ion RT) have been created with the relative biological effectiveness (RBE) of human salivary gland cells (HSG). However, no dose distributions have been created using various tumor cell-specific RBE values. Hence, we conducted in vitro experiments to determine the RBE of human osteosarcoma cells (U2OS) and used this RBE value (RBEU2OS) to calculate the dose distribution for C-ion RT.
MATERIALS AND
METHODS
To obtain RBE values for various linear energy transfer (LET) levels, we exposed U2OS cells to different doses of X-rays and varying doses and LET levels of C-ion beams (13, 30, 50, and 70 keV/μm). Subsequently, we converted the RBE of HSG (RBEHSG) to RBEU2OS in the treatment planning system and reconstructed the dose distribution for a typical osteosarcoma case. We performed a dose-volume histogram (DVH) analysis, evaluating the percentage of the minimum dose that covered 98%, 50%, and 2% (D98%, D50%, and D2%, respectively), as well as the homogeneity index [HI; calculated as (D2%-D98%)/D50%].
RESULTS
The RBEU2OS values for C-ion beams with LET of 13, 30, 50, and 70 keV/μm were 1.77, 2.25, 2.72, and 4.50, respectively. When comparing DVH parameters with the planning target volume, we observed the following values: D98%, D50%, D2%, and HI for RBEHSG were 64.1, 70.1, 72.4 Gy (RBE), and 0.12, respectively. For RBEU2OS, these values were 86.2, 95.0, 107.9 Gy (RBE), and 0.23, respectively.
CONCLUSION
We utilized RBEU2OS to calculate the dose distribution of carbon ion radiotherapy, revealing potential degradation in dose distribution and particularly worsening of the HI.