MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/d5sc04507j

Медицинская библиотека · Chemical science · 2025

Enhancing the reverse intersystem crossing (RISC) rates and efficiencies of MR-TADF emitters with a U-shaped molecular structure for solution-processed OLEDs.

Xu Shipan, Liu Wenping, Yan An, Du Xuyang, Sun Yuanhui, Tao Junfei, Zhou Guijiang, Chen Zhao, Yang Xiaolong

СтатьяПеревод пока не подготовлен

Аннотация

Multi-resonance thermally activated delayed fluorescence (MR-TADF) emitters hold great potential for applications in organic light-emitting diodes (OLEDs). However, owing to their inherently rigid and planar molecular structures and the localized charge transfer (LCT) characteristics, these emitters typically exhibit poor solubility and low reverse intersystem crossing (RISC) rates, which are unfavorable for high-performance solution-processed OLEDs. Herein, we constructed three U-shaped MR-TADF emitters (BN-N-TTz, BN-N-PCz and BN-N-BN) by introducing triazine, phenylcarbazole and MR-TADF units at the 1- and 8-positions of a naphthalene ring. This U-shaped molecular architecture endows the emitters with excellent solubility. Moreover, this structure not only enhances spin-orbit coupling between the S1 and T1 states but also reduces the energy difference between the two states (ΔE ST), thereby increasing RISC rates to as high as 3.17 × 105 s-1. Notably, the solution-processed OLED based on BN-N-BN achieved the highest EQE of 27.6% without sensitizers. This represents one of the best performances among solution-processed OLEDs based on MR-TADF emitters to date. This simple approach reveals the great potential for developing solution-processable emitters suitable for high-performance rigid and planar molecular structures.

Для цитирования: Xu Shipan, Liu Wenping, Yan An, Du Xuyang, Sun Yuanhui, Tao Junfei, Zhou Guijiang, Chen Zhao, Yang Xiaolong. Enhancing the reverse intersystem crossing (RISC) rates and efficiencies of MR-TADF emitters with a U-shaped molecular structure for solution-processed OLEDs.. Chemical science. 2025. DOI: 10.1039/d5sc04507j.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.