BACKGROUND

Cardiac surgery has become a possible cause of ascending aortic dissection, particularly in patients who have undergone aortic valve replacement.

METHODS

From January 1979 to December 1989, 134 patients with angiographic evidence of aortic dissection, were studied in the Haemodinamic Laboratory of the University of Turin. Twelve of these patients (7 men and 5 women), mean age 51.6 years, had been previously operated for aortic valve replacement. We evaluated incidence, clinical and anatomic features of ascending aortic dissection in this group.

RESULTS

A dilated ascending aorta with a mean diameter of 4.92 cm. was noted in all these patients. The interval between valve replacement and diagnosis of aortic dissection was 57 months (range 1 day to 9 years). Reoperation was performed in 11 patients. Four intraoperative deaths occurred and 2 other patients died in the early post-operative period. Survival rate at 12 months was 50%. Our incidence of ascending aortic dissection after aortic valve replacement was 0.66% (10 patients out of 1499 operated for aortic valve replacement) and it is in agreement with reports from other Authors in literature.

CONCLUSIONS

Replacement of the ascending aorta must be considered if an important dilatation of aortic root is found at time of aortic valve surgery. New efforts must be undertaken to identify patients at high risk for this complication because an elevated mortality rate is observed in reoperation for aortic dissection.

Для цитирования: Presbitero P, Aruta E, Rabajoli F, Agaccio G, Donegani E, Orzan F, Malara D, Di Summa M, Morea M. [Aortic dissection after aortic valve replacement: clinical and anatomic features].. Giornale italiano di cardiologia. 1992.