MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0735-1097(97)00210-6

Медицинская библиотека · Journal of the American College of Cardiology · 1997

Calculation of aortic regurgitant volume by a new digital Doppler color flow mapping method: an animal study with quantified chronic aortic regurgitation.

Shiota T, Jones M, Aida S, Tsujino H, Yamada I, Delabays A, Pandian N G, Sahn D J

Сравнительное исследованиеСтатьяПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of the present study was to quantitate aortic regurgitant volume and regurgitant fraction in a chronic animal model with surgically created aortic regurgitation using a new semiautomated color Doppler flow calculation method.

BACKGROUND

The conventional noninvasive methods for evaluating the severity of aortic regurgitation have not been accepted widely nor compared with truly quantitative reference standards.

METHODS

Eight to 20 weeks after aortic regurgitation was surgically induced in six sheep, a total of 22 hemodynamic states were studied. Electromagnetic flow probes and meters provided reference flow data. Epicardial color Doppler echocardiographic studies were performed to image left ventricular outflow tract forward and aortic regurgitant blood flows. The new method digitally integrated spatial and temporal color flow velocity data for left ventricular outflow tract forward flow and ascending aortic regurgitant flow. The pulsed Doppler method using the velocity-time integral was also used to obtain regurgitant volumes and regurgitant fractions.

RESULTS

Regurgitant volumes and regurgitant fractions by the new method agreed well with those obtained electromagnetically, whereas the pulsed Doppler method overestimated these reference data (mean [+/-SD] difference 0.23 +/- 2.9 ml vs. 11 +/- 5.8 ml, p < 0.0001 for regurgitant volume; mean difference 1.2 +/- 7.6% vs. 19 +/- 13%, p < 0.0001 for regurgitant fraction).

CONCLUSIONS

This animal study, using strictly quantified aortic regurgitant volumes, demonstrated that the digital color Doppler method provides accurate aortic regurgitant volumes and regurgitant fractions without cumbersome measurements.

Для цитирования: Shiota T, Jones M, Aida S, Tsujino H, Yamada I, Delabays A, Pandian N G, Sahn D J. Calculation of aortic regurgitant volume by a new digital Doppler color flow mapping method: an animal study with quantified chronic aortic regurgitation.. Journal of the American College of Cardiology. 1997. DOI: 10.1016/s0735-1097(97)00210-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.