Аннотация

OBJECTIVES

Nitric oxide (NO) measured in the gaseous phase has been shown to be a marker of inflammation in the urinary bladder. The NO content of air incubated in the bladder can be measured in an NO analyzer. The aim of our study was threefold: to evaluate whether NO can be measured in air incubated in a catheter balloon, to determine the optimal time of incubation, and to find the most suitable type of catheter.

METHODS

The NO concentration in air introduced directly into the bladder and into the catheter balloon was measured in patients with and without bladder infections. The air was incubated for 5 to 60 minutes. NO concentration in the bladder of patients with interstitial cystitis was also analyzed. The diffusion rate of NO through silicon and latex catheters was studied.

RESULTS

Elevated NO levels were detected in the urinary bladder in patients with bladder inflammation due to infection or interstitial cystitis. A marked increase in NO concentration was found after just 5 minutes of incubation and continued to rise for up to 20 minutes, both in air taken directly from the bladder and from the catheter balloon. The NO diffusion rate into the balloons of silicon catheters was high; the recovery rate in latex catheters was poor.

CONCLUSIONS

Measurement of NO concentration in a silicon balloon catheter inserted into the urinary bladder is a fast, convenient, and reliable method to detect inflammation.

Для цитирования: Ehrén I, Hosseini A, Herulf M, Lundberg J O, Wiklund N P. Measurement of luminal nitric oxide in bladder inflammation using a silicon balloon catheter: a novel minimally invasive method.. Urology. 1999. DOI: 10.1016/s0090-4295(99)00120-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.