MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacep.2018.06.021

Медицинская библиотека · JACC. Clinical electrophysiology · 2018

Prospective Multicenter Experience With Cooled Radiofrequency Ablation Using High Impedance Irrigant to Target Deep Myocardial Substrate Refractory to Standard Ablation.

Nguyen Duy T, Tzou Wendy S, Sandhu Amneet, Gianni Carola, Anter Elad, Tung Roderick, Valderrábano Miguel, Hranitzky Patrick, Soeijma Kyoko, Saenz Luis, Garcia Fermin C, Tedrow Usha B, Miller John M, Gerstenfeld Edward P, Burkhardt J David, Natale Andrea, Sauer William H

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study sought to evaluate the efficacy and safety of using half-normal saline (HNS) as the cooling radiofrequency ablation (RFA) irrigant among patients who had failed prior, standard RFA.

BACKGROUND

Effective control of ventricular arrhythmias that arise from mid-myocardium may be refractory to standard RFA. Recent data suggest that delivering fluid with decreased ionic concentration during open-irrigated RFA can produce deeper RFA lesions.

METHODS

A 12-center prospective analysis was performed of all ablations using HNS for the treatment of ventricular arrhythmias (premature ventricular complex [PVC]/ventricular tachycardia [VT]) refractory to standard ablation with normal saline irrigant.

RESULTS

HNS RFA was used clinically to target 94 PVC/VTs refractory to standard ablation. Acute success was achieved in 78 of 94 (83%), with longer-term success occurring in 78 subjects after a mean follow-up of 6.1 ± 6.7 months (range, 3.0 to 25.2 months). Steam pops were observed among 12 (12.6%) patients. There were no significant changes in electrolytes measured before and after the use of HNS, and there were no complications related to HNS use.

CONCLUSIONS

The use of HNS instead of normal saline irrigant during high-power delivery targeting deep myocardial substrate is safe and effective. PVC/VT sources previously unaffected by standard ablation may be successfully ablated with improved efficiency of radiofrequency delivery using HNS.

Для цитирования: Nguyen Duy T, Tzou Wendy S, Sandhu Amneet, Gianni Carola, Anter Elad, Tung Roderick, Valderrábano Miguel, Hranitzky Patrick, Soeijma Kyoko, Saenz Luis, Garcia Fermin C, Tedrow Usha B, Miller John M, Gerstenfeld Edward P, Burkhardt J David, Natale Andrea, Sauer William H. Prospective Multicenter Experience With Cooled Radiofrequency Ablation Using High Impedance Irrigant to Target Deep Myocardial Substrate Refractory to Standard Ablation.. JACC. Clinical electrophysiology. 2018. DOI: 10.1016/j.jacep.2018.06.021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.