Infarct-Related Ventricular Tachycardia: Redefining the Electrophysiological Substrate of the Isthmus During Sinus Rhythm.

Anter Elad, Kleber Andre G, Rottmann Markus, Leshem Eran, Barkagan Michael, Tschabrunn Cory M, Contreras-Valdes Fernando M, Buxton Alfred E

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

OBJECTIVES

In this study, the scientific objective was to characterize the electrophysiological substrate of the ventricular tachycardia (VT) isthmus during sinus rhythm.

BACKGROUND

The authors have recently described the electrophysiological characteristics of the VT isthmus using a novel in vivo high-resolution mapping technology.

METHODS

Sixteen swine with healed infarction were studied using high-resolution mapping technology (Rhythmia, Boston Scientific, Cambridge, Massachusetts) in a closed-chest model. The left ventricle was mapped during sinus rhythm and analyzed for activation, conduction velocity, electrogram shape, and amplitude. Twenty-four VTs allowed detailed mapping of the common-channel "isthmus," including the "critical zone." This was defined as the zone of maximal conduction velocity slowing in the circuit, often occurring at entrance and exit from the isthmus caused by rapid angular change in activation vectors.

RESULTS

The VT isthmus corresponded to sites displaying steep activation gradient (SAG) during sinus rhythm with conduction velocity slowing of 58.5 ± 22.4% (positive predictive value [PPV] 60%). The VT critical zone displayed SAG with greater conduction velocity slowing of 68.6 ± 18.2% (PPV 70%). Critical-zone sites were consistently localized in areas with bipolar voltage ≤0.55 mV, whereas isthmus sites were localized in areas with variable voltage amplitude (1.05 ± 0.80 mV [0.03 to 2.88 mV]). Importantly, critical zones served as common-site "anchors" for multiple VT configurations and cycle lengths. Isthmus and critical-zone sites occupied only 18.0 ± 7.0% of the low-voltage area (≤1.50 mV). Isolated late potentials were present in both isthmus and nonisthmus sites, including dead-end pathways (PPV 36%; 95% confidence interval: 34.2% to 39.6%).

CONCLUSIONS

The VT critical zone corresponds to a location characterized by SAG and very low voltage amplitude during sinus rhythm. Thus, it allows identification of a re-entry anchor with high sensitivity and specificity. By contrast, voltage and electrogram characteristics during sinus rhythm have limited specificity for identifying the VT isthmus.

Для цитирования: Anter Elad, Kleber Andre G, Rottmann Markus, Leshem Eran, Barkagan Michael, Tschabrunn Cory M, Contreras-Valdes Fernando M, Buxton Alfred E. Infarct-Related Ventricular Tachycardia: Redefining the Electrophysiological Substrate of the Isthmus During Sinus Rhythm.. JACC. Clinical electrophysiology. 2018. DOI: 10.1016/j.jacep.2018.04.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.