DOI 10.1016/j.jacep.2017.12.005
Multicenter Study of Ischemic Ventricular Tachycardia Ablation With Decrement-Evoked Potential (DEEP) Mapping With Extra Stimulus.
Аннотация
OBJECTIVES
The authors conducted a multicenter study of decrement-evoked potential (DEEP)-based functional ventricular tachycardia (VT) substrate modification to evaluate if such a mechanistic and physiological strategy is feasible and efficient in clinical practice and provides reduction in the VT burden.
BACKGROUND
Only a fraction of the myocardium targeted in current VT substrate modification procedures is involved in the initiation and perpetuation of VT. The physiological basis of the DEEP strategy for identification of areas of initiation and maintenance of VT was recently established.
METHODS
We included 20 consecutive patients with ischemic cardiomyopathy. During substrate mapping, fractionated and late potentials (LPs) were tagged, and an extra stimulus was performed to determine which LPs displayed decrement (DEEPs). All patients underwent DEEP-focused ablation: elimination of DEEP + further radiofrequency (RF) if VT was still inducible. Patients were followed during 6 months.
RESULTS
Patients were predominantly male (95%), and their mean age was 64.6 ± 17.1 years. Mean left ventricular ejection fraction was 33.4 ± 11.4%. Mean ablation time was 30.6 ± 20.4 min. Specificity of DEEPs to detect the isthmus of VT was better than that of LPs (0.97 [95% confidence interval [CI]: 0.95 to 0.98] vs. 0.82 [95% CI: 0.73 to 0.89]), without significant differences in terms of sensitivity (0.61 [95% CI: 0.52 to 0.69] vs. 0.60 [95% CI: 0.44 to 0.74], respectively). Fifteen of 20 (75%) patients were free of any VT after DEEP-RF at 6 months of follow-up and there was a strong reduction in VT burden compared to 6 months pre-ablation.
CONCLUSIONS
In a multicenter prospective study, DEEP substrate mapping identified the functional substrate critical to the VT circuit with high specificity. DEEP-guided VT ablation, by its physiological nature, may enable greater access to focused ablation therapy for patients requiring VT treatment.