Evaluation of the pulmonary artery potential using a 20-polar circumferential catheter and three-dimensional integrated intracardiac echocardiography.

Takahashi Masayuki, Yokoshiki Hisashi, Mitsuyama Hirofumi, Tenma Taro, Watanabe Masaya, Kamada Rui, Sasaki Ryo, Chiba Yuki, Maeno Motoki, Anzai Toshihisa

СтатьяПеревод пока не подготовлен

Аннотация

Prolongation of the pulmonary artery potentials (PAPs) in response to short coupling intervals was related to polymorphic QRS configurations during the ventricular tachycardia originating above the pulmonary valve (PA-VT). This prospective study was aimed to investigate the mechanisms of polymorphic changes during the PA-VT. We performed the mapping above the pulmonary valve using a 20-polar circumferential catheter and three-dimensional integrated intracardiac echocardiography in 9 consecutive patients with outflow tract arrhythmias undergoing catheter ablation (UMIN ID: UMIN000021682). The location of successful ablation was right ventricular outflow tract (RVOT) in 6 patients, above the pulmonary valve in 1 patient, left coronary cusp in 1 patient, and unknown in 1 patient. The PAP was detected in six (67%) patients with bipolar voltage of 0.56 ± 0.27 mV. Pacing from bipolar electrodes of the circumferential catheter located above the pulmonary valve captured the PA myocardium only in 1 patient who had the PA-VT (100% in PA-VT vs 0% in non-PA-VT, P = 0.0046), and slight changes of the QRS morphology was observed in accordance with the conduction delay from the stimulus to activation of the RVOT myocardium. The selective PAP capture with conduction delays evoked by bipolar stimulations through a 20-polar circumferential catheter may be a characteristic property of patients with the PA-VT. Conduction delays within the PA and PA-RVOT junction appears to contribute polymorphic QRS changes during the PA-VT.

Для цитирования: Takahashi Masayuki, Yokoshiki Hisashi, Mitsuyama Hirofumi, Tenma Taro, Watanabe Masaya, Kamada Rui, Sasaki Ryo, Chiba Yuki, Maeno Motoki, Anzai Toshihisa. Evaluation of the pulmonary artery potential using a 20-polar circumferential catheter and three-dimensional integrated intracardiac echocardiography.. Heart and vessels. 2018. DOI: 10.1007/s00380-018-1209-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.