MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jcpt.12717

Медицинская библиотека · Journal of clinical pharmacy and therapeutics · 2018

Lidocaine toxicity in the setting of HeartMate II left ventricular assist device.

Tunney R K, Whyte K, DeAntonio H J

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

WHAT IS KNOWN AND

OBJECTIVE

Lidocaine infused at 1-4 mg/min is an appropriate treatment modality for hemodynamically stable ventricular tachycardia (VT) with normal hepatic function. A case of acute lidocaine toxicity in the setting of left ventricular assist device (LVAD) is reported.

CASE SUMMARY: A 71-year-old with a HeartMate II LVAD on chronic mexiletine and normal liver function presented with ventricular tachycardia requiring systemic lidocaine and subsequently developed altered mental status with tremors. A lidocaine level obtained within 24 hours of infusion initiation was 7.9 mcg/mL.

WHAT IS NEW AND

CONCLUSION

This case highlights the potential for marked deviation from published pharmacokinetic parameters for a narrow therapeutic window agent with concurrent LVAD.

Для цитирования: Tunney R K, Whyte K, DeAntonio H J. Lidocaine toxicity in the setting of HeartMate II left ventricular assist device.. Journal of clinical pharmacy and therapeutics. 2018. DOI: 10.1111/jcpt.12717.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.