MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3791/51881

Медицинская библиотека · Journal of visualized experiments : JoVE · 2015

Catheterization of the carotid artery and jugular vein to perform hemodynamic measures, infusions and blood sampling in a conscious rat model.

Feng Jing, Fitz Yvonne, Li Yan, Fernandez Melinda, Cortes Puch Irene, Wang Dong, Pazniokas Stephanie, Bucher Brandon, Cui Xizhong, Solomon Steven B

СтатьяResearch Support, N.I.H., IntramuralПоддержка исследования: вне правительства СШАVideo-Audio MediaПеревод пока не подготовлен

Аннотация

The success of a small animal model to study critical illness is, in part, dependent on the ability of the model to simulate the human condition. Intra-tracheal inoculation of a known amount of bacteria has been successfully used to reproduce the pathogenesis of pneumonia which then develops into sepsis. Monitoring hemodynamic parameters and providing standard clinical treatment including infusion of antibiotics, fluids and drugs to maintain blood pressure is critical to simulate routine supportive care in this model but to do so requires both arterial and venous vascular access. The video details the surgical technique for implanting carotid artery and common jugular vein catheters in an anesthetized rat. Following a 72 hr recovery period, the animals will be re-anesthetized and connected to a tether and swivel setup attached to the rodent housing which connects the implanted catheters to the hemodynamic monitoring system. This setup allows free movement of the rat during the study while continuously monitoring pressures, infusing fluids and drugs (antibiotics, vasopressors) and performing blood sampling.

Для цитирования: Feng Jing, Fitz Yvonne, Li Yan, Fernandez Melinda, Cortes Puch Irene, Wang Dong, Pazniokas Stephanie, Bucher Brandon, Cui Xizhong, Solomon Steven B. Catheterization of the carotid artery and jugular vein to perform hemodynamic measures, infusions and blood sampling in a conscious rat model.. Journal of visualized experiments : JoVE. 2015. DOI: 10.3791/51881.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.