MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/diagnostics14242854

Медицинская библиотека · Diagnostics (Basel, Switzerland) · 2024

Lumen-Apposing Metal Stents in the Management of Complex Pelvic Abscesses.

Chow Kenneth W, Cumpian Nicholas A, Makar Ranjit, Zargar Pejman, Oza Fouzia, Suliman Idrees, Eysselein Viktor, Reicher Sofiya

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Lumen-apposing metal stents (LAMS) are utilized in a wide range of therapeutic gastrointestinal applications. We present our experience with LAMS-assisted drainage of complex pelvic abscesses at a large safety-net hospital.

METHODS

EUS-guided LAMS placements for pelvic abscesses from July 2020 to June 2024 were analyzed. Data were collected on patient demographics, procedure indications, fluid collection size, stent characteristics, stent dwell time, and complications. All cases underwent multidisciplinary review with Surgery and Interventional Radiology (IR) prior to LAMS-assisted drainage; all were deemed not amenable to drainage by IR.

RESULTS

Eleven patients underwent EUS-guided drainage of complex pelvic abscesses with cautery-enhanced LAMS. Diverticulitis was the most common cause of abscesses (n = 6; 55%). The average time from presentation to drainage was 7 days (1-18). The average abscess size was 7.2 cm (3.9-12.0 cm). The most common LAMS size was 15 mm × 10 mm; each was placed through the left colon and rectum with both technical and clinical success. All abscesses completely resolved with a mean stent dwell time of 28 days (17-42 days). After stent removal, the fistula was not routinely closed. No complications such as stent migration, bleeding, or perforation occurred. There were no recurrences and no patients required additional surgical or IR procedures with a mean follow-up of 25 weeks (SD 35.6).

CONCLUSIONS

Adequate drainage is the cornerstone of pelvic abscess management, but IR or surgical access can be challenging, with inadequate drainage and prolonged hospitalization leading to significant morbidity. In our experience, EUS-guided, LAMS-assisted drainage provides a safe and effective alternative for managing pelvic abscesses.

Для цитирования: Chow Kenneth W, Cumpian Nicholas A, Makar Ranjit, Zargar Pejman, Oza Fouzia, Suliman Idrees, Eysselein Viktor, Reicher Sofiya. Lumen-Apposing Metal Stents in the Management of Complex Pelvic Abscesses.. Diagnostics (Basel, Switzerland). 2024. DOI: 10.3390/diagnostics14242854.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.