MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.amjcard.2013.02.055

Медицинская библиотека · The American journal of cardiology · 2013

Two-year follow-up of outcomes of second-generation everolimus-eluting stents versus first-generation drug-eluting stents for stenosis of saphenous vein grafts used as aortocoronary conduits.

Kitabata Hironori, Loh Joshua P, Pendyala Lakshmana K, Badr Salem, Dvir Danny, Barbash Israel M, Minha Sa'ar, Torguson Rebecca, Chen Fang, Satler Lowell F, Suddath William O, Kent Kenneth M, Pichard Augusto D, Waksman Ron

СтатьяПеревод пока не подготовлен

Аннотация

Second-generation everolimus-eluting stents (EESs) have demonstrated superiority in efficacy and safety compared with first-generation drug-eluting stents (DESs) in the treatment of native coronary artery lesions. The present study evaluated and compared the safety and efficacy of EESs and first-generation DESs in saphenous vein graft lesions. The EES group consisted of 88 patients with 96 lesions, and the first-generation DES group consisted of 243 patients with 317 lesions (sirolimus-eluting stents, n = 212; paclitaxel-eluting stents, n = 105). The end points included target lesion revascularization, target vessel revascularization, major adverse cardiovascular events (composite of all-cause death, myocardial infarction, and target vessel revascularization), and definite stent thrombosis at 2 years. The groups had similar baseline characteristics and graft ages (128.1 ± 77.5 vs 132.4 ± 90.8 months, p = 0.686). The EES group had more type C lesions and less embolic protection device use. The peak postprocedure values of creatinine kinase-MB and troponin I were similar between the 2 groups. Overall, major adverse cardiovascular events occurred in 18.2% of EES patients and 35.0% of first-generation DES patients (p = 0.003), mainly driven by a lower target vessel revascularization rate (6.8% vs 24.5%, p <0.001). The target lesion revascularization rate was lower in the EES group (1.1% vs 11.6%, p = 0.005). Stent thrombosis was low and similar between the 2 groups (0% vs 0.8%, p = 1.000). On multivariate analysis, the type of DES implanted and graft age were the only independent predictors of major adverse cardiovascular events. In conclusion, the superiority of EESs compared with first-generation DESs shown in native artery lesions has been extended to saphenous vein graft lesions and should be considered as the DES of choice for this lesion type.

Для цитирования: Kitabata Hironori, Loh Joshua P, Pendyala Lakshmana K, Badr Salem, Dvir Danny, Barbash Israel M, Minha Sa'ar, Torguson Rebecca, Chen Fang, Satler Lowell F, Suddath William O, Kent Kenneth M, Pichard Augusto D, Waksman Ron. Two-year follow-up of outcomes of second-generation everolimus-eluting stents versus first-generation drug-eluting stents for stenosis of saphenous vein grafts used as aortocoronary conduits.. The American journal of cardiology. 2013. DOI: 10.1016/j.amjcard.2013.02.055.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.