MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0954411912461239

Медицинская библиотека · Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2013

A finite element investigation on plaque vulnerability in realistic healthy and atherosclerotic human coronary arteries.

Karimi Alireza, Navidbakhsh Mahdi, Faghihi Shahab, Shojaei Ahmad, Hassani Kamran

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Atherosclerosis is the most common arterial disease. It has been shown that stresses that are induced during blood circulation can cause plaque rupture and, in turn, lead to thrombosis and stroke. In this study, finite element method is used to predict plaque vulnerability based on peak plaque stress using human samples. A total of 23 healthy and atherosclerotic human coronary arteries of 14 healthy and 9 atherosclerotic patients are excised within 5 h postmortem. The samples are mounted on an uniaxial tensile test machine, and the obtained mechanical properties are used in two-dimensional and three-dimensional finite element models. The results including the Neo-Hookean hyperelastic coefficients of the samples as well as peak plaque stresses are analyzed. The results indicate that the atherosclerotic human coronary arteries have significantly (p < 0.05) higher stiffness compared with the healthy ones. The hypocellular plaque also has the highest stress values and, as a result, is most likely (vulnerable) to rupture, while the calcified type has the lowest stress values and, consequently, is expected to remain stable. The results could be used in the plaque vulnerability anticipation and have clinical implications in interventions and surgeries, including balloon angioplasty, bypass, and stenting.

Для цитирования: Karimi Alireza, Navidbakhsh Mahdi, Faghihi Shahab, Shojaei Ahmad, Hassani Kamran. A finite element investigation on plaque vulnerability in realistic healthy and atherosclerotic human coronary arteries.. Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine. 2013. DOI: 10.1177/0954411912461239.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.