The international journal of cardiovascular imaging · 2013
Very long-term follow-up of strut apposition and tissue coverage with Biolimus A9 stents analyzed by optical coherence tomography.
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Staico Rodolfo, Costa Marco A, Chamié Daniel, Bezerra Hiram, Armaganijan Luciana V, Costa Ricardo A, Costa José Ribamar, Siqueira Dimytri, Centemero Marinella, Chaves Áurea, Tanajura Luiz Fernando, Abizaid Alexandre, Feres Fausto, Sousa J Eduardo M R, Sousa Amanda G M R
Аннотация
First generation drug-eluting stents (DES) are associated with reduced in-stent restenosis but significant increased risk of very late stent thrombosis (VLST). The absence of polymer in DES systems may reduce the occurrence of VLST. Optic coherence tomography (OCT) has been used for stent analysis as a surrogate safety endpoint. This study aimed to assess the long-term follow up of strut apposition and tissue coverage of BioMatrix DES by OCT. 20 patients undergoing BioMatrix DES (n = 15) or S-Stent BMS (n = 5) implantation were followed for at least 5 years and evaluated by quantitative coronary angiography, intravascular ultrasound, and OCT. The difference between the stent types was evaluated by nonparametric Mann-Whitney U test while categorical variables were evaluated by Fisher exact test. Rates of in-stent late loss were similar between groups [0.40 (0.21;0.77) vs. 0.68 (0.66; 0.82) mm, p = 0.205, for BioMatrix and S-Stent, respectively]. The vessel, stent and lumen volumes did not differ between groups. Patients treated with BioMatrix had significantly less stent obstruction [5.6 (4.4;9.7) vs. 28.6 (24.7;29.0) %, p = 0.001]. OCT analysis of 12 stents (Biomatrix = 9 and S-Stent = 3) demonstrated 126 (8.7 %) uncovered struts in the BioMatrix group compared to 23 (4.0 %) in the S-Stent group (p = 0.297), being the majority of them well apposed (117/126 and 21/23, respectively, p = 0.292). Only 9 (0.6 %) struts in the DES and 2 (0.4 %) struts in the BMS groups were simultaneously uncovered and malapposed (p = 0.924). BioMatrix DES was associated with lower rates of in-stent obstruction, and similar percentage of neointimal coverage on struts and of complete strut apposition.
Предметные рубрики MeSH
AgedCardiovascular AgentsCoronary AngiographyCoronary Artery DiseaseCoronary RestenosisCoronary VesselsDrug-Eluting StentsFemaleHumansMaleMiddle AgedNeointimaPercutaneous Coronary InterventionPredictive Value of TestsProsthesis DesignSirolimusTime FactorsTomography, Optical CoherenceTreatment OutcomeUltrasonography, Interventional