m+Medelevator.RU
← Поиск публикаций
The international journal of cardiovascular imaging · 2013

Optical coherence tomography guided in-stent thrombus removal in patients with acute coronary syndromes.

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Di Giorgio Alessandro, Capodanno Davide, Ramazzotti Vito, Imola Fabrizio, Mallus Maria Teresa, Stazi Filippo, Paoletti Giulia, Biondi-Zoccai Giuseppe, Tamburino Corrado, Prati Francesco

Аннотация

The persistence of thrombus inside stent struts is a frequent event in patients with acute coronary syndromes (ACS) undergoing percutaneous coronary intervention (PCI), and this phenomenon might be associated with an increased risk of stent thrombosis. We sought to quantify by means of optical coherence tomography (OCT) the presence of in-stent thrombus after achievement of an optimal angiographic result in patients with ACS undergoing PCI. In addition, we evaluated the feasibility and safety of an OCT-guided strategy of in-stent thrombus removal. Eighty consecutive patients with ACS undergoing PCI were treated with two different strategies equally divided into two groups: angio-guided PCI, and OCT-guided PCI, in which additional OCT-driven in-stent balloon dilatation was adopted to reduce thrombus encroachment of the lumen. Overall in-stent thrombus area was 4.3 % with a maximal thrombus encroachment of 16.7 %. In the OCT-guided group, use of high pressure intra-stent dilatation led to a significant increase in stented area (9.6 ± 2.4 vs. 9.1 ± 2.49 mm(2), p = 0.002) and lumen area (9.2 ± 2.4 vs. 8.7 ± 2.3 mm(2), p < 0.001) and also significantly decreased in-stent thrombus area in absolute (0.35 ± 0.29 vs. 0.42 ± 0.30 mm(2), p = 0.001) and relative terms (3.58 ± 3.25 vs. 4.53 ± 3.01 %, p = 0.001). Values of TIMI flow, frame count and blush grade, as well as clinical outcomes were not detrimentally affected by such additional dilatations. The use of additional OCT-driven in-stent balloon dilatations is feasible, safe and might be effective in the treatment of in-stent thrombus for patients with ACS.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты