Arterial repair 4 months after zotarolimus-eluting stent implantation observed on angioscopy.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Ishihara Takayuki, Awata Masaki, Sera Fusako, Fujita Masashi, Watanabe Tetsuya, Iida Osamu, Ishida Yoshio, Nanto Shinsuke, Uematsu Masaaki
Аннотация
BACKGROUND: Arterial repair in the early phase following implantation of a zotarolimus-eluting stent (ZES) remains unknown.
METHODS AND RESULTS: Following implantation of 49 Endeavor ZES in 33 patients, follow-up angioscopy was performed in 13 patients (26 ZES) in the early phase (EP; 123±24 days) and in 20 patients (23 ZES) in the middle phase (MP; 247±17 days). Neointimal coverage (NIC) was graded as follows: grade 0, stent struts exposed; grade 1, struts bulging into the lumen, although covered; grade 2, struts were embedded by the neointima but were seen translucently; grade 3, struts fully embedded and invisible. NIC was defined as heterogeneous for NIC grade variation≥1. The presence of thrombus and yellow plaque was also investigated. Although NIC heterogeneity tended to be more frequent in EP than in MP (50% vs. 22%, P=0.070), and yellow plaque significantly more frequent (58% vs. 13%, P=0.0025), the majority of stents were dominant NIC grade 3 at both follow-up periods (73% in EP vs. 78% in MP, P=0.75). There was no significant difference in thrombus (23% in EP vs. 4% in MP, P=0.10) between the follow-ups.
CONCLUSIONS: Sufficient arterial repair may have occurred by 4 months after ZES implantation.
METHODS AND RESULTS: Following implantation of 49 Endeavor ZES in 33 patients, follow-up angioscopy was performed in 13 patients (26 ZES) in the early phase (EP; 123±24 days) and in 20 patients (23 ZES) in the middle phase (MP; 247±17 days). Neointimal coverage (NIC) was graded as follows: grade 0, stent struts exposed; grade 1, struts bulging into the lumen, although covered; grade 2, struts were embedded by the neointima but were seen translucently; grade 3, struts fully embedded and invisible. NIC was defined as heterogeneous for NIC grade variation≥1. The presence of thrombus and yellow plaque was also investigated. Although NIC heterogeneity tended to be more frequent in EP than in MP (50% vs. 22%, P=0.070), and yellow plaque significantly more frequent (58% vs. 13%, P=0.0025), the majority of stents were dominant NIC grade 3 at both follow-up periods (73% in EP vs. 78% in MP, P=0.75). There was no significant difference in thrombus (23% in EP vs. 4% in MP, P=0.10) between the follow-ups.
CONCLUSIONS: Sufficient arterial repair may have occurred by 4 months after ZES implantation.
Предметные рубрики MeSH
AgedAged, 80 and overAngioscopyCardiovascular AgentsChi-Square DistributionCoronary AngiographyCoronary ThrombosisCoronary VesselsDrug-Eluting StentsFemaleHumansMaleMiddle AgedNeointimaPercutaneous Coronary InterventionPredictive Value of TestsProsthesis DesignRisk FactorsSirolimusTime FactorsTreatment Outcome