MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1088/2057-1976/ae9cc2

Медицинская библиотека · Biomedical physics & engineering express · 2026

Dual-energy cone-beam CT improves iodine contrast and Hounsfield unit value stability in the maxillofacial region: a phantom study.

Jayakody Dinidu, Riekki Veli-Pekka, Bode Michaela K, Brix Mikael A K

СтатьяПеревод в очереди

Аннотация

This study was designed to assess the feasibility of dual-energy cone-beam computed tomography (DE-CBCT) and the associated image processing algorithms to improve delayed phase iodine enhancement. An anthropomorphic adult head phantom with iodine inserts in maxillofacial regions was imaged using a clinical CBCT and a helical CT scanner. DE-CBCT was acquired sequentially at 80 and 120 kV, and helical CT at 100 kV (routine clinical protocol), with radiation doses matched within 5%. Virtual monochromatic images (VMIs) at 50 and 200 keV were generated with (VMI+) and without (VMI) noise-optimized frequency splitting algorithm. Evaluation included Hounsfield Unit (HU) agreement with helical CT, iodine contrast, contrast-to-noise ratio (CNR), artifact reduction, and subjective radiologist assessment of target visibility. VMI50 and VMI50+ demonstrated the strongest HU agreement with CT. VMI50+ produced significantly better contrast than CBCT in the maxillary sinus region (mean percentage change 40.7% (15.3%-66.1%);p< 0.05), while improvements were minor in the mandibular region (9.7% (3.0%-16.5%);p< 0.05). VMI50+ significantly increased CNR in the maxillary sinus compared with CBCT (3.3 vs 2.8;p< 0.05), with no significant difference in the mandibular region. Although DE-CBCT increased contrast and reduced artifacts, it did not reveal any additional targets compared with routine CBCT. DE-CBCT with VMI and frequency splitting improves HU agreement with CT, slightly improves soft tissue visualization, and reduces artifacts in head and neck phantom imaging.

Для цитирования: Jayakody Dinidu, Riekki Veli-Pekka, Bode Michaela K, Brix Mikael A K. Dual-energy cone-beam CT improves iodine contrast and Hounsfield unit value stability in the maxillofacial region: a phantom study.. Biomedical physics & engineering express. 2026. DOI: 10.1088/2057-1976/ae9cc2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.