MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circep.109.933051

Медицинская библиотека · Circulation. Arrhythmia and electrophysiology · 2010

Extraction of old pacemaker or cardioverter-defibrillator leads by laser sheath versus femoral approach.

Bordachar Pierre, Defaye Pascal, Peyrouse Eric, Boveda Serge, Mokrani Bilel, Marquié Christelle, Barandon Laurent, Fossaert Emilie Marcant, Garrigue Stephane, Reuter Sylvain, Laborderie Julien, Marijon Eloi, Deharo Jean-Claude, Jacon Peggy, Kacet Salem, Ploux Sylvain, Deplagne Antoine, Haissaguerre Michel, Clementy Jacques, Ritter Philippe, Klug Didier

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Some operators routinely extract chronically implanted transvenous leads from a femoral, whereas others prefer a superior approach. This prospective study compared the safety and effectiveness of laser sheaths versus femoral snare extractions.

METHODS AND

RESULTS

The single-center study comprised 101 patients referred for unequivocal indications to extract > or =1 transvenous lead(s). Patients were >4 years of age and were randomly assigned to extractions with a laser sheath (group 1: n=50) versus a snare via femoral approach (group 2: n=51). The multicenter study comprised 358 patients who underwent extraction of old transvenous leads using laser sheaths (n=218, group 3) in 3 centers and from a femoral approach (n=138, group 4) in 3 other centers. In the single-center study, the success and complications rates were similar in groups 1 and 2. No patient died of a periprocedural complication. The procedural duration (51+/-22 versus 86+/-51 minutes) and duration of total fluoroscopic exposure (7+/-7 versus 21+/-17 minutes) were significantly shorter (each P<0.01) in group I than in group 2. In the multicenter study, we observed 2 procedure-associated deaths in group 3 versus 1 in group 4. Major procedural complications were observed in 3% of patients in group 3, versus 3% in group 4 (P=NS). The rates of complete, partial, and unsuccessful extractions were similar in groups 3 and 4.

CONCLUSIONS

Old transvenous leads were extracted with similar success and complication rates by the femoral and laser approaches. However, the femoral approach was associated with longer procedures and a longer duration of fluoroscopic exposure.

Для цитирования: Bordachar Pierre, Defaye Pascal, Peyrouse Eric, Boveda Serge, Mokrani Bilel, Marquié Christelle, Barandon Laurent, Fossaert Emilie Marcant, Garrigue Stephane, Reuter Sylvain, Laborderie Julien, Marijon Eloi, Deharo Jean-Claude, Jacon Peggy, Kacet Salem, Ploux Sylvain, Deplagne Antoine, Haissaguerre Michel, Clementy Jacques, Ritter Philippe, Klug Didier. Extraction of old pacemaker or cardioverter-defibrillator leads by laser sheath versus femoral approach.. Circulation. Arrhythmia and electrophysiology. 2010. DOI: 10.1161/circep.109.933051.