MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2010.03.026

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2010

The impact of bridge-to-transplant ventricular assist device support on survival after cardiac transplantation.

Bull David A, Reid Bruce B, Selzman Craig H, Mesley Rebecca, Drakos Stavros, Clayson Steven, Stoddard Greg, Gilbert Edward, Stehlik Josef, Bader Feras, Kfoury Abdallah, Budge Deborah, Eckels David D, Fuller Anne, Renlund Dale, Patel Amit N

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To determine the impact of bridge-to-transplant ventricular assist device support on survival after cardiac transplantation.

METHODS

From January 1, 1993, to April 30, 2009, a total of 525 cardiac transplants were performed. Ventricular assist devices were placed as a bridge to transplant in 110 patients. We focused our analysis on the 2 most common causes of end-stage heart failure requiring transplantation: idiopathic dilated cardiomyopathy (n = 201) and coronary artery disease (n = 213). Data including gender, age, date of transplant, cause of heart failure, prior heart transplant, placement of a ventricular assist device, type of ventricular assist device, and panel-reactive antibody sensitization were analyzed to derive Kaplan-Meier survival probabilities and multivariable Cox regression models.

RESULTS

In patients with idiopathic dilated cardiomyopathy who received a ventricular assist device as a bridge to transplant, survival was decreased at 1 year (P = .008) and 5 years (P = .019), but not at 10 years, posttransplant. In patients with coronary artery disease, the use of a ventricular assist device as a bridge to transplant did not influence survival at 1, 5, and 10 tears posttransplant. In patients with idiopathic dilated cardiomyopathy who received a Heartmate I (Thoratec Corp, Pleasanton, Calif) ventricular assist device as a bridge to a cardiac transplant, elevation in the pretransplant panel-reactive antibody correlated with a decrease in long-term survival.

CONCLUSION

In patients with idiopathic dilated cardiomyopathy, placement of a Heartmate I ventricular assist device as a bridge to a cardiac transplant is associated with an elevation in the pretransplant panel-reactive antibody and a decrease in 1- and 5-year survivals after cardiac transplantation.

Для цитирования: Bull David A, Reid Bruce B, Selzman Craig H, Mesley Rebecca, Drakos Stavros, Clayson Steven, Stoddard Greg, Gilbert Edward, Stehlik Josef, Bader Feras, Kfoury Abdallah, Budge Deborah, Eckels David D, Fuller Anne, Renlund Dale, Patel Amit N. The impact of bridge-to-transplant ventricular assist device support on survival after cardiac transplantation.. The Journal of thoracic and cardiovascular surgery. 2010. DOI: 10.1016/j.jtcvs.2010.03.026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.