MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Turk Kardiyoloji Dernegi arsivi : Turk Kardiyoloji Derneginin yayin organidir · 2009

[The frequency of prosthesis-patient mismatch after mechanical mitral valve replacement and its effect on postoperative systolic pulmonary arterial pressure].

Tuğcu Aylin, Köse Ozkan, Yildirimtürk Ozlem, Tayyareci Yelda, Aytekin Saide

Аннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

We investigated the frequency of prosthesis-patient mismatch (PPM) after mechanical mitral valve replacement (MVR), its effect on postoperative systolic pulmonary arterial pressure (PAP), and the relationship of indexed effective orifice area (EOA) with systolic PAP and hemodynamic variables of the prosthetic valve.

STUDY

DESIGN

The study included 100 patients (27 men, 73 women; mean age 51+/-11 years) with a normally functioning mechanical mitral valve prosthesis. Prosthetic mitral EOA, indexed EOA, and net atrioventricular compliance (Cn) were estimated by Doppler echocardiography. Prosthesis-patient mismatch was defined as an indexed EOA <or=1.2 cm2/m2 and Cn <or=4 ml/mmHg, and pulmonary hypertension (PHT) was defined as systolic PAP >or=40 mmHg.

RESULTS

The frequencies of PPM and postoperative persistent PHT were 33% and 31%, respectively. Postoperative persistent PHT was seen in 79% and 8% in patients with and without PPM, respectively (p<0.001). The frequency of low Cn was significantly higher in patients with PPM (60% vs. 31%; p<0.001). Postoperative systolic PAP was significantly higher in patients with PPM (42.0+/-6.6 mmHg vs. 29.9+/-6.0 mmHg, p<0.0001) and in 41 patients having a low Cn compared to 59 patients having a high Cn (37.2+/-8.8 mmHg vs. 31.6+/-7.4 mmHg, p<0.001). Postoperative systolic PAP was significantly correlated with indexed EOA (r=-0.535, p<0.001) and Cn (r=-0.422, p<0.001), whereas prosthetic valve size was not correlated with systolic PAP (r=0.022, p=0.829) and indexed EOA (r=0.008, p=0.93). In multivariate regression analysis, indexed EOA, age, mean transprosthetic gradient, and Cn were independent factors affecting systolic PAP.

CONCLUSION

Prosthesis-patient mismatch after MVR is associated with persistent PHT. Use of a prosthetic valve that is compatible to the body surface area may significantly reduce the incidence of PPM, and thus the frequency of persistent PHT.

Для цитирования: Tuğcu Aylin, Köse Ozkan, Yildirimtürk Ozlem, Tayyareci Yelda, Aytekin Saide. [The frequency of prosthesis-patient mismatch after mechanical mitral valve replacement and its effect on postoperative systolic pulmonary arterial pressure].. Turk Kardiyoloji Dernegi arsivi : Turk Kardiyoloji Derneginin yayin organidir. 2009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.