MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2008.10.027

Медицинская библиотека · The Annals of thoracic surgery · 2009

Platelet dysfunction in outpatients with left ventricular assist devices.

Steinlechner Barbara, Dworschak Martin, Birkenberg Beatrice, Duris Monika, Zeidler Petra, Fischer Henrik, Milosevic Ljubisa, Wieselthaler Georg, Wolner Ernst, Quehenberger Peter, Jilma Bernd

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Thromboembolic and bleeding complications in outpatients with a left ventricular assist device are common and can be detrimental. A meticulous balance between anticoagulant and procoagulant factors is therefore crucial. However, in contrast to routinely performed plasmatic coagulation tests, platelet function is hardly ever monitored although recent reports indicated platelet dysfunction. We therefore differentially evaluated platelet function with four commonly used point-of-care devices.

METHODS

In a cross-sectional design platelet function was assessed in 12 outpatients and 12 healthy matched volunteers using thrombelastography platelet mapping, thromboelastometry, platelet function analyzer, and a new whole blood aggregometer (Multiplate).

RESULTS

Phenprocoumon produced an international normalized ratio of 3.5. It was associated with a twofold prolongation in the thromboelastometry clotting time (p < 0.001). Platelet function under high shear was severely compromised: collagen adenosine diphosphate closure times were 2.5-fold longer in patients than in volunteers (p < 0.001), and 50% of patients had maximal collagen adenosine diphosphate closure time values. Although antigen levels of von Willebrand factor were 80% higher in patients (p < 0.001), von Willebrand factor-ristocetin was subnormal in 5 of 12 patients. Ristocetin-induced aggregation was also threefold higher in volunteers (p < 0.001), indicating an additional functional defect of platelets affecting the glycoprotein Ib-von Willebrand factor axis. The von Willebrand factor multimer pattern in patients also appeared abnormal.

CONCLUSIONS

Multimodal antiplatelet monitoring showed markedly impaired platelet function in patients with a left ventricular assist device. Platelet dysfunction under high shear rates and abnormal ristocetin-induced aggregation is only partly attributable to low von Willebrand factor activity. These findings resemble the acquired von Willebrand syndrome that is associated with microaggregate formation and enhanced bleeding.

Для цитирования: Steinlechner Barbara, Dworschak Martin, Birkenberg Beatrice, Duris Monika, Zeidler Petra, Fischer Henrik, Milosevic Ljubisa, Wieselthaler Georg, Wolner Ernst, Quehenberger Peter, Jilma Bernd. Platelet dysfunction in outpatients with left ventricular assist devices.. The Annals of thoracic surgery. 2009. DOI: 10.1016/j.athoracsur.2008.10.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.