MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10047-021-01294-0

Медицинская библиотека · Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2021

A three-dimensional biomodel of type A aortic dissection for endovascular interventions.

Arakawa Mamoru, Sumikura Hirohito, Okamura Homare, Miyagawa Atsushi, Homma Akihiko, Yamaguchi Atsushi

СтатьяПеревод пока не подготовлен

Аннотация

Thoracic endovascular aortic repair is widely used for type B aortic dissection. However, there is no favorable stent-graft for type A aortic dissection. A significant limitation for device development is the lack of an experimental model for type A aortic dissection. We developed a novel three-dimensional biomodel of type A aortic dissection for endovascular interventions. Based on Digital Imaging and Communication in Medicine data from the computed tomography image of a patient with a type A aortic dissection, a three-dimensional biomodel with a true lumen, a false lumen, and an entry tear located at the ascending aorta was created using laser stereolithography and subsequent vacuum casting. The biomodel was connected to a pulsatile mock circuit. We conducted four tests: an endurance test for clinical hemodynamics, wire insertion into the biomodel, rapid pacing, and simulation of stent-graft placement. The biomodel successfully simulated clinical hemodynamics; the target blood pressure and cardiac output were achieved. The guidewire crossed both true and false lumens via the entry tear. The pressure and flow dropped upon rapid pacing and recovered after it was stopped. This simulation biomodel detected decreased false luminal flow by stent-graft placement and detected residual leak. The three-dimensional biomodel of type A aortic dissection with a pulsatile mock circuit achieved target clinical hemodynamics, demonstrated feasibility for future use during the simulated endovascular procedure, and evaluated changes in the hemodynamics.

Для цитирования: Arakawa Mamoru, Sumikura Hirohito, Okamura Homare, Miyagawa Atsushi, Homma Akihiko, Yamaguchi Atsushi. A three-dimensional biomodel of type A aortic dissection for endovascular interventions.. Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs. 2021. DOI: 10.1007/s10047-021-01294-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.