MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1024/0301-1526/a000980

Медицинская библиотека · VASA. Zeitschrift fur Gefasskrankheiten · 2021

BioMimics 3D vascular stent system for femoropopliteal interventions.

Lichtenberg Michael, Zeller Thomas, Gaines Peter, Piorkowski Michael, MIMICS-3D investigators

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

Background

The MIMICS-3D study aimed to assess the safety and effectiveness of the BioMimics 3D Vascular Stent System for the treatment of symptomatic femoropopliteal artery disease in a real-world patient population. Patients and methods: Consecutive participants who were scheduled for implantation of the BioMimics 3D stent were enrolled in the prospective, observational, multicenter study. The primary effectiveness outcome was freedom from clinically driven target lesion revascularization at 12 months and the primary safety outcome was a composite of major adverse events comprising death, major target limb amputation, or clinically driven target lesion revascularization at 30 days. Outcomes through 24 months are reported.

Results

A total of 507 patients (70±10 years, 65.5% male sex) were enrolled and treated with the study stent. 24.0% had critical limb-threatening ischemia, lesion length was 127±92 mm, and 56.8% of lesions were totally occluded. The Kaplan-Meier (KM) estimate of freedom from clinically driven target lesion revascularization at twelve-months was 90.6% (95% CI: 87.9%-93.3%) and the 30-day primary safety outcome occurred in 1.2% (95% CI: 0.5%-2.7%) of participants. At 24 months, clinical improvement was achieved in 86.6% and the KM estimate of freedom from clinically driven target lesion revascularization was 82.8% (95% CI: 79.4%-86.4%). The KM estimate of freedom from loss of primary patency according to PSVR >2.4 was 78.6% (95% CI: 74.7%-82.4%). Survival distribution functions regarding primary patency were lower with long lesions (>150 mm; log-rank p<0.001) but did not differ significantly between participants with or without critical limb-threatening ischemia (log-rank p=0.07).

Conclusions

Endovascular treatment of atherosclerotic femoropopliteal lesions with the BioMimics 3D Vascular Stent System is efficacious and safe in a real-world setting.

Для цитирования: Lichtenberg Michael, Zeller Thomas, Gaines Peter, Piorkowski Michael, MIMICS-3D investigators. BioMimics 3D vascular stent system for femoropopliteal interventions.. VASA. Zeitschrift fur Gefasskrankheiten. 2021. DOI: 10.1024/0301-1526/a000980.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.