MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jmri.21249

Медицинская библиотека · Journal of magnetic resonance imaging : JMRI · 2008

In vivo diffusion tensor imaging of the rat spinal cord at 9.4T.

Ellingson Benjamin M, Kurpad Shekar N, Li Shi-Jiang, Schmit Brian D

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

PURPOSE: To determine differences in diffusion measurements in white matter (WM) and gray matter (GM) regions of the rat cervical, thoracic, and cauda equina spinal cord using in vivo diffusion tensor imaging (DTI) with a 9.4T MR scanner.

MATERIALS AND

METHODS

DTI was performed on seven rats in three slices at the cervical, thoracic, and cauda equina regions of the spinal cord using a 9.4T magnet. Axial diffusion weighted images (DWIs) were collected at a b-value of 1000 seconds/mm(2) in six directions. Regions of interest were identified via T2-weighted images for the lateral, dorsal, and ventral funiculi, along with GM regions.

RESULTS

Analysis of variance (ANOVA) results indicated significant differences between every WM funiculus compared to GM for longitudinal apparent diffusion coefficient (lADC), transverse apparent diffusion coefficient (tADC), fractional anisotropy (FA), measured longitudinal anisotropy (MA1), and anisotropy index (AI). A significant difference in mean diffusivity (MD) between regions of the spinal cord was not found. Diffusion measurements were significantly different at each spinal level. In general, GM regions were significantly different than WM regions; however, there were few significant differences between individual WM regions.

CONCLUSION

In vivo DTI of the rat spinal cord at 9.4T appears sensitive to the architecture of neural structures in the rat spinal cord and may be a useful tool in studying trauma and pathologies in the spinal cord.

Для цитирования: Ellingson Benjamin M, Kurpad Shekar N, Li Shi-Jiang, Schmit Brian D. In vivo diffusion tensor imaging of the rat spinal cord at 9.4T.. Journal of magnetic resonance imaging : JMRI. 2008. DOI: 10.1002/jmri.21249.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.