Recurrence Following Globe Sparing Excision for Basal Cell Carcinoma with Anterior Orbital Invasion.

Tong Jessica Y, Martin Peter A, Tumuluri Krishna, Selva Dinesh

СтатьяПеревод в очереди

Аннотация

PURPOSE: Globe-sparing excision for periocular basal cell carcinoma (BCC) with orbital invasion has evident benefits, but the ensuing morbidity and characteristics of recurrence are not well elucidated. This study aims to describe the extent of visual morbidity following globe-sparing excision, and the clinicoradiological characteristics of tumor recurrence.

METHODS

Multicentre retrospective case series.

RESULTS

Eight patients were identified for inclusion in this series. Time to recurrence following globe-sparing excision ranged from 3 to 12 years. Seven patients (87.5%) presented with recurrent disease originating from the medial canthus. Clinical features at presentation included contracture ( n =4, 50.0%), upper lid ptosis ( n =3, 37.5%), a palpable mass ( n =2, 25.0%), and hypoesthesia ( n =2, 25.0%). Radiologically, tumor recurrence was predominantly characterized by isointense signals on T1 and T2-weighted sequences ( n =5, 62.5%) with moderate contrast enhancement. The most common histologic subtype in recurrent tumors was a mixed nodular and infiltrative growth pattern ( n =5, 62.5%). Perineural invasion was a feature in four (50%) cases. Salvage therapy in the form of exenteration was performed in seven cases. Vismodegib and adjuvant radiotherapy were provided for one case with surgically unresectable tumor recurrence.

CONCLUSIONS

Globe-sparing excision for invasive periocular BCC can be complicated by late recurrence that develops rapidly despite silent neuroimaging for years. Early clinical signs are subtle. High-risk features predictive of recurrence include medial canthus location, mixed histological subtypes, and perineural invasion. Patients with such characteristics require lifelong clinical and imaging surveillance following globe-sparing excision.

Для цитирования: Tong Jessica Y, Martin Peter A, Tumuluri Krishna, Selva Dinesh. Recurrence Following Globe Sparing Excision for Basal Cell Carcinoma with Anterior Orbital Invasion.. Ophthalmic plastic and reconstructive surgery. 2023. DOI: 10.1097/iop.0000000000002328.