MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2021.04.013

Медицинская библиотека · Heart rhythm · 2021

Utility of cardiovascular implantable electronic device-derived patient activity to predict clinical outcomes.

Rosero Spencer Z, Younis Arwa, Jones Paul, McNitt Scott, Goldenberg Ilan, Zareba Wojciech, Stein Kenneth, Kutyifa Valentina

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The role of cardiovascular implantable electronic device (CIED)-derived activity to predict implantable cardioverter-defibrillator (ICD) therapy or death is not known.

OBJECTIVE

We aimed to assess CIED-derived activity to predict clinical outcomes.

METHODS

In 1500 patients enrolled in MADIT-RIT, CIED-derived patient activity was acquired daily, then averaged for the first 30 days following randomization to predict inappropriate/appropriate therapy or death. Kaplan-Meier analysis and Cox proportional regression models were used to evaluate inappropriate/appropriate therapy, heart failure, or death by 30-day CIED-derived patient activity quintiles.

RESULTS

There were 1463 patients with CIED activity data (98%). Patients in the highest quintile (Q5) of activity (more active) had the highest rate of inappropriate therapy, 21% at 2 years, as compared to 7%-11% in the other 4 quintiles (P < .001), a 1.75 times higher risk (95% confidence interval [CI]: 1.23-2.50, P = .002). However, patients in the lowest quintile of activity (Q1, 1 hour/day) had the highest risk of mortality, 15% in 2 years, as compared to Q2-3 (1-2 hours/day, 8%-7% mortality), and Q4-5 (>2 hours/day, 2%-3% mortality) (P < .001). Patients with the lowest level of activity (Q1) had a 2.02 times higher risk of mortality (95% CI: 1.21-3.38, P = .007), and they had an 82% higher risk of heart failure hospitalization (95% CI: 1.28-2.57, P = .001).

CONCLUSIONS

High CIED-derived 30-day median patient activity predicted inappropriate therapy, while low patient activity predicted mortality and heart failure in ICD and cardiac resynchronization therapy with defibrillator patients enrolled in MADIT-RIT. Device-derived activity assessment could serve as a useful predictor of outcomes.

Для цитирования: Rosero Spencer Z, Younis Arwa, Jones Paul, McNitt Scott, Goldenberg Ilan, Zareba Wojciech, Stein Kenneth, Kutyifa Valentina. Utility of cardiovascular implantable electronic device-derived patient activity to predict clinical outcomes.. Heart rhythm. 2021. DOI: 10.1016/j.hrthm.2021.04.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.