DOI 10.1016/j.bjps.2015.06.027
Correlation between indocyanine green (ICG) patterns and real-time elastography images in lower extremity lymphedema patients.
Аннотация
BACKGROUND/AIM: Indocyanine green (ICG) lymphography is becoming a popular modality, but unfortunately it is not available in all institutions. Elastography is a relatively new ultrasonographic technique to evaluate tissue elasticity, which visualizes fluid retention as a red region in lymphedema patients. The aim of this study was to evaluate the correlation between elastography and ICG lymphology.
METHODS
Thirty-six legs in 18 patients with secondary lower extremity lymphedema (LEL) and 20 legs in 10 healthy volunteers were examined using elastography. Thirty-six legs in 18 secondary LEL patients were examined using ICG lymphography. Elastography was performed on both legs at the following three sites: medial thigh (MT), medial leg (ML), and anterior ankle (AA). The area of the red region in the subcutaneous tissue demonstrated by elastography was calculated using Image software. ICG lymphography findings were classified into the following four patterns: linear (ICG1), splash (ICG2), stardust (ICG3), and diffuse (ICG4) patterns.
RESULTS
As ICG pattern progressed, the red region area was likely to increase. There was a correlation between ICG patterns and red region area according to the severity at bilateral MT (rs = 0.665), ML (rs = 0.623), and AA (rs = 0.668). Significant difference was demonstrated among group means of the red region area by analysis of variance (healthy vs. ICG1 vs. ICG2 vs. ICG3 vs. ICG 4: 14.4 ± 5.7 vs. 15.1 ± 10.3 vs. 25.2 ± 6.2 vs. 30.8 ± 9.4 vs. 35.0 ± 2.8; P < 0.001).
CONCLUSIONS
The area of the red region in the subcutaneous tissue shown using elastography, which represents fluid, increases with the aggravation of lymphedema demonstrated by ICG patterns. As elastography is performed by ultrasonography, which is available in most institutions, elastography could be a useful alternative evaluation for lymphedema severity when ICG lymphography is not available.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.