MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1098/rsif.2015.0280

Медицинская библиотека · Journal of the Royal Society, Interface · 2015

Quantification of the passive and active biaxial mechanical behaviour and microstructural organization of rat thoracic ducts.

Caulk Alexander W, Nepiyushchikh Zhanna V, Shaw Ryan, Dixon J Brandon, Gleason Rudolph L

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

Mechanical loading conditions are likely to play a key role in passive and active (contractile) behaviour of lymphatic vessels. The development of a microstructurally motivated model of lymphatic tissue is necessary for quantification of mechanically mediated maladaptive remodelling in the lymphatic vasculature. Towards this end, we performed cylindrical biaxial testing of Sprague-Dawley rat thoracic ducts (n = 6) and constitutive modelling to characterize their mechanical behaviour. Spontaneous contraction was quantified at transmural pressures of 3, 6 and 9 cmH2O. Cyclic inflation in calcium-free saline was performed at fixed axial stretches between 1.30 and 1.60, while recording pressure, outer diameter and axial force. A microstructurally motivated four-fibre family constitutive model originally proposed by Holzapfel et al. (Holzapfel et al. 2000 J. Elast. 61, 1-48. (doi:10.1023/A:1010835316564)) was used to quantify the passive mechanical response, and the model of Rachev and Hayashi was used to quantify the active (contractile) mechanical response. The average error between data and theory was 8.9 ± 0.8% for passive data and 6.6 ± 2.6% and 6.8 ± 3.4% for the systolic and basal conditions, respectively, for active data. Multi-photon microscopy was performed to quantify vessel wall thickness (32.2 ± 1.60 µm) and elastin and collagen organization for three loading conditions. Elastin exhibited structural 'fibre families' oriented nearly circumferentially and axially. Sample-to-sample variation was observed in collagen fibre distributions, which were often non-axisymmetric, suggesting material asymmetry. In closure, this paper presents a microstructurally motivated model that accurately captures the biaxial active and passive mechanical behaviour in lymphatics and offers potential for future research to identify parameters contributing to mechanically mediated disease development.

Для цитирования: Caulk Alexander W, Nepiyushchikh Zhanna V, Shaw Ryan, Dixon J Brandon, Gleason Rudolph L. Quantification of the passive and active biaxial mechanical behaviour and microstructural organization of rat thoracic ducts.. Journal of the Royal Society, Interface. 2015. DOI: 10.1098/rsif.2015.0280.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.