A patient-friendly 16-channel transmit/64-channel receive coil array for combined head-neck MRI at 7 Tesla.

May Markus W, Hansen Sam-Luca J D, Mahmutovic Mirsad, Scholz Alina, Kutscha Nicolas, Guerin Bastien, Stockmann Jason P, Barry Robert L, Kazemivalipour Ehsan, Gumbrecht Rene, Kimmlingen Ralph, Adriany Markus, Chang Yulin, Triantafyllou Christina, Knake Susanne, Wald Lawrence L, Keil Boris

СтатьяПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

PURPOSE: To extend the coverage of brain coil arrays to the neck and cervical-spine region to enable combined head and neck imaging at 7 Tesla (T) ultra-high field MRI.

METHODS

The coil array structures of a 64-channel receive coil and a 16-channel transmit coil were merged into one anatomically shaped close-fitting housing. Transmit characteristics were evaluated in a B1+ -field mapping study and an electromagnetic model. Receive SNR and the encoding capability for accelerated imaging were evaluated and compared with a commercially available 7 T brain array coil. The performance of the head-neck array coil was demonstrated in human volunteers using high-resolution accelerated imaging.

RESULTS

In the brain, the SNR matches the commercially available 32-channel brain array and showed improvements in accelerated imaging capabilities. More importantly, the constructed coil array improved the SNR in the face area, neck area, and cervical spine by a factor of 1.5, 3.4, and 5.2, respectively, in regions not covered by 32-channel brain arrays at 7 T. The interelement coupling of the 16-channel transmit coil ranged from -14 to -44 dB (mean = -19 dB, adjacent elements <-18 dB). The parallel 16-channel transmit coil greatly facilitates B1+ field shaping required for large FOV neuroimaging at 7 T.

CONCLUSION

This new head-neck array coil is the first demonstration of a device of this nature used for combined full-brain, head-neck, and cervical-spine imaging at 7 T. The array coil is well suited to provide large FOV images, which potentially improves ultrahigh field neuroimaging applications for clinical settings.

Для цитирования: May Markus W, Hansen Sam-Luca J D, Mahmutovic Mirsad, Scholz Alina, Kutscha Nicolas, Guerin Bastien, Stockmann Jason P, Barry Robert L, Kazemivalipour Ehsan, Gumbrecht Rene, Kimmlingen Ralph, Adriany Markus, Chang Yulin, Triantafyllou Christina, Knake Susanne, Wald Lawrence L, Keil Boris. A patient-friendly 16-channel transmit/64-channel receive coil array for combined head-neck MRI at 7 Tesla.. Magnetic resonance in medicine. 2022. DOI: 10.1002/mrm.29288.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.