MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/iop.0000000000002209

Медицинская библиотека · Ophthalmic plastic and reconstructive surgery · 2022

Quantitative Analysis of Preoperative and Postoperative Photographs Posted on Social Media by Oculoplastic Surgeons.

Maamari Robi N, Farhood Zachary, Holds John B, Couch Steven M

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate and quantitatively analyze preoperative and postoperative photographs posted on social media by oculoplastic surgeons.

METHODS

Pre- and postoperative blepharoplasty photographs posted by oculoplastic surgeons on the social media platform Instagram were identified over a 4-month period. Photographs demonstrating a frontal pose of the periocular region were selected, and image analysis was performed to compare the preoperative and postoperative photographs. Quantitative image analysis was performed with a semiautomated script using ImageJ (v1.52k) software. Image analysis compared magnification, patient position, luminosity, relative color profiles, and edge detection/sharpness. Three oculoplastic surgeons graded these imaging metrics for the same photoset and the consensus grade was assigned to each category. Finally, the quantitative calculations were then compared with the consensus grades to develop receiver operating characteristic curves for further analysis.

RESULTS

The study included 104 posts from 35 members of ASOPRS. Regarding patient positioning, 9 postings were 5%-10% offset from the patients' center, and 6 postings were more than 10% from the patients' center. The majority of photosets demonstrated less than or equal to 2.5% difference in magnification (69/104), with 7 postings demonstrating a greater than 5% difference, and 3 postings exhibiting greater than 10% difference in magnification. In the periocular region, 17.3% (18/104) of postings were found to have a greater than 10% difference in luminosity (>25.5 pixel-value). A more than 5% difference (>12.75 pixel-value) in pre- and postoperative edge-detection measurements was identified in 12 of 104 postings. In 22 of 104 photosets, the mean absolute deviation in color channel ratios was more than 0.01 and 15 of 104 photosets were found to have a mean absolute deviation more than 0.05.

CONCLUSIONS

Numerous quantifiable photographic inconsistencies were identified in surgical photographs posted on social media by members of ASOPRS. Adoption of an automated image analysis tool that compares before-and-after surgical photographs could promote standardized oculoplastic surgery photography on social media.

Для цитирования: Maamari Robi N, Farhood Zachary, Holds John B, Couch Steven M. Quantitative Analysis of Preoperative and Postoperative Photographs Posted on Social Media by Oculoplastic Surgeons.. Ophthalmic plastic and reconstructive surgery. 2022. DOI: 10.1097/iop.0000000000002209.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление