m+Medelevator.RU
← Поиск публикаций
Clinical otolaryngology : official journal of ENT-UK ; official journal of Netherlands Society for Oto-Rhino-Laryngology & Cervico-Facial Surgery · 2022

Feasibility of face mask spirometry during decannulation in head and neck surgery: Prospective cohort study.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sánchez-Guerrero José Antonio, Cebrià I Iranzo Maria Àngels, Ferrer-Sargues Francisco José, Périé Sophie

Аннотация

OBJECTIVES: To analyse the relationship between spirometric parameters measured with a face mask versus a mouthpiece, as well as the feasibility of face mask spirometric evaluation in a head and neck surgery (HNS) decannulation context. Furthermore, we examine peak inspiratory flow (PIF) cut-off values before and after decannulation.

DESIGN: Prospective cohort study.

SETTING: Otolaryngology HNS Department of a university teaching hospital.

PARTICIPANTS: Twenty-four patients were selected. A maximal flow-volume loop was conducted before (with mouthpiece) and after (with mouthpiece and face mask) decannulation.

MAIN OUTCOME MEASURES: Recorded outcomes were forced vital capacity (FVC), forced expiratory volume in the first second, peak expiratory flow, PIF, forced expiratory flow at 50% of FVC and forced inspiratory flow at 50% of FVC. Spearman correlation coefficients between spirometric parameters measured with a face mask versus a mouthpiece were calculated. Wilcoxon test was used to check differences between mouthpiece and face mask values.

RESULTS: Correlation between mouthpiece and face mask spirometric values was moderate to high (r = 0.46-0.95). All parameters measured by spirometry were significantly lower with a face mask than those obtained with a mouthpiece (p < 0.05). Before decannulation, the lowest PIF value (tested with mouthpiece) that allowed successful decannulation was 1 L/s. After decannulation, the lowest PIF value tested with mouthpiece and face mask for successful completion of the decannulation process were 0.77 and 0.56 L/s, respectively.

CONCLUSION: Face mask is a feasible option to perform a spirometry when face diseases hinder spirometric evaluation through a mouthpiece in an HNC surgery context.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты