MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jbm.b.32810

Медицинская библиотека · Journal of biomedical materials research. Part B, Applied biomaterials · 2012

Introduction of a high-throughput double-stent animal model for the evaluation of biodegradable vascular stents.

Borinski Mauricio, Flege Christian, Schreiber Fabian, Krott Nicole, Gries Thomas, Liehn Elisa, Blindt Rüdiger, Marx Nikolaus, Vogt Felix

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Current stent system efficacy for the treatment of coronary artery disease is hampered by in-stent restenosis (ISR) rates of up to 20% in certain high-risk settings and by the risk of stent thrombosis, which is characterized by a high mortality rate. In theory, biodegradable vascular devices exhibit crucial advantages. Most absorbable implant materials are based on poly-L-lactic acid (PLLA) owing to its mechanical properties; however, PLLA might induce an inflammatory reaction in the vessel wall. Evaluation of biodegradable implant efficacy includes a long-term examination of tissue response; therefore, a simple in vivo tool for thorough biocompatibility and biodegradation evaluation would facilitate future stent system development. Rats have been used for the study of in vivo degradation processes, and stent implantation into the abdominal aorta of rats is a proven model for stent evaluation. Here, we report the transformation of the porcine double-stent animal model into the high-throughput rat abdominal aorta model. As genetic manipulation of rats was introduced recently, this novel method presents a powerful tool for future in vivo biodegradable candidate stent biocompatibility and biodegradation characterization in a reliable simple model of coronary ISR.

Для цитирования: Borinski Mauricio, Flege Christian, Schreiber Fabian, Krott Nicole, Gries Thomas, Liehn Elisa, Blindt Rüdiger, Marx Nikolaus, Vogt Felix. Introduction of a high-throughput double-stent animal model for the evaluation of biodegradable vascular stents.. Journal of biomedical materials research. Part B, Applied biomaterials. 2012. DOI: 10.1002/jbm.b.32810.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.