Third metal stent for revision of malignant hilar biliary strictures.
Аннотация
Background and study aim: Endoscopic stent-in-stent (SIS) placement of multiple metal stents is technically demanding. In the present study, we explored the technical feasibility and efficacy of endoscopic deployment of a third metal stent to create a triple SIS placement in patients with a bilateral SIS configuration for inoperable high grade malignant hilar biliary stricture (HBS) that had failed clinically.
Methods
Eighteen patients with histologically proven inoperable HBS underwent deployment of an additional third metal stent as a revisionary method after early clinical failure following technically successful bilateral SIS placement using cross-wired metal stents. The main outcome measures were the technical and clinical success rates, and adverse events.
Results
The overall technical and clinical success rates were 88.9 % (16/18) and 87.5 % (14/16), respectively. The early and late complications were cholangitis (n = 2) and cholecystitis (n = 1). Stent occlusion developed in 35.7 % (5/14) of patients in whom a third metal stent for revision of a bilateral SIS configuration was clinically successful. The median (range) times for stent patency and patient survival were 176 days (49 - 372) and 216 days (52 - 384), respectively.
Conclusions
Endoscopic deployment of an additional third metal stent into a bilateral SIS configuration was technically feasible and effective in patients with inoperable high grade malignant HBS in whom bilateral SIS placement had failed clinically.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.