MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/lbr.0b013e31826e361c

Медицинская библиотека · Journal of bronchology & interventional pulmonology · 2012

Endobronchial ultrasound-guided transbronchial needle aspiration: determinants of sampling adequacy.

DePew Zachary S, Edell Eric S, Midthun David E, Mullon John J, Bungum Aaron O, Decker Paul A, Maldonado Fabien, Mayo Pulmonary Procedural Group

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is increasingly used to sample mediastinal and hilar lymph nodes and has excellent diagnostic test characteristics. The determinants of sampling adequacy, however, have not been extensively examined. We set out to determine which procedural variables were associated with acquisition of tissue sufficient for pathologic analysis during EBUS-TBNA.

METHODS

A retrospective analysis of all EBUS-TBNA cases performed over 32 months by 10 proceduralists at our institution was completed. Variables potentially associated with sampling adequacy were analyzed.

RESULTS

A total of 1304 procedures performed by 10 proceduralists while the patient received conscious sedation were included for analysis. Sampling adequacy was 94.2% overall and varied with the primary proceduralist (87% to 99.2%; P<0.001). Diagnostic yield per procedure for malignancy or a specific benign diagnosis was 43.2% overall. Proceduralists with a higher average number of lymph node stations sampled per procedure had improved sampling adequacy (parameter estimate=1.32; P=0.007). Sampling adequacy was lower with lymph nodes smaller than 10 mm (parameter estimate=-0.7; P=0.002) but was not associated with procedural environment (hospital procedural suite vs. clinic-based procedural suite) (P=0.08), lymph node station (P=0.69), propofol use (P=0.90), or average annual proceduralist cases performed (P=0.21). Only 6/216 (2.8%) patients had subsequent procedures (EBUS-TBNA or surgery) that indicated the initial EBUS-TBNA had inadequate sampling potentially leading to a missed cancer diagnosis.

CONCLUSIONS

Excellent EBUS-TBNA sampling adequacy can be achieved by pulmonologists in a large group setting, who are not exclusively dedicated to interventional pulmonary medicine, using only moderate conscious sedation.

Для цитирования: DePew Zachary S, Edell Eric S, Midthun David E, Mullon John J, Bungum Aaron O, Decker Paul A, Maldonado Fabien, Mayo Pulmonary Procedural Group. Endobronchial ultrasound-guided transbronchial needle aspiration: determinants of sampling adequacy.. Journal of bronchology & interventional pulmonology. 2012. DOI: 10.1097/lbr.0b013e31826e361c.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.