DOI 10.1378/chest.11-0692

Медицинская библиотека · Chest · 2012

Randomized clinical trial of endobronchial ultrasound needle biopsy with and without aspiration.

Casal Roberto F, Staerkel Gregg A, Ost David, Almeida Francisco A, Uzbeck Mateen H, Eapen George A, Jimenez Carlos A, Nogueras-Gonzalez Graciela M, Sarkiss Mona, Morice Rodolfo C

СтатьяРандомизированное исследованиеПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

BACKGROUND

Endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration (EBUS-TBNA) is performed with a dedicated 22- or 21-gauge needle while suction is applied. Fine-needle sampling without suction (capillary sampling) has been studied for endoscopic ultrasound and for biopsies at various body sites and has resulted in similar diagnostic yield and fewer traumatic samples. However, the role of EBUS-guided transbronchial needle capillary sampling (EBUS-TBNCS) is still to be determined.

METHODS

Adults with suspicious hilar or mediastinal lymph nodes (LNs) were included in a single-blinded, prospective, randomized trial comparing EBUS-TBNA and EBUS-TBNCS. The primary end point was the concordance rate between the two techniques in terms of adequacy and diagnosis of cytologic samples. The secondary end point was the concordance rate between the two techniques in terms of quality of samples.

RESULTS

A total of 115 patients and 192 LNs were studied. Concordance between EBUS-TBNA and EBUS-TBNCS was high, with no significant difference in adequacy (88% vs 88%, respectively [P ± .858]; concordance rate, 83.9% [95% CI, 77.9-88.8]); diagnosis (36% vs 34%, respectively [P ± .289]; concordance rate, 95.8% [95% CI, 92-92.8]); diagnosis of malignancy (28% vs 26%, respectively [P ± .125]; concordance rate, 97.9% [95% CI, 94.8-99.4]); or sample quality (concordance rate, 83.3% [95% CI, 73.3-88.3]). Concordance between EBUS-TBNA and EBUS-TBNCS was high irrespective of LN size (≤ 1 cm vs > 1 cm).

CONCLUSIONS

Regardless of LN size, no differences in adequacy, diagnosis, or quality were found between samples obtained using EBUS-TBNA and those obtained using EBUS-TBNCS. There is no evidence of any benefit derived from the practice of applying suction to EBUS-guided biopsies.

TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT00886847; URL: www.clinicaltrials.gov

Для цитирования: Casal Roberto F, Staerkel Gregg A, Ost David, Almeida Francisco A, Uzbeck Mateen H, Eapen George A, Jimenez Carlos A, Nogueras-Gonzalez Graciela M, Sarkiss Mona, Morice Rodolfo C. Randomized clinical trial of endobronchial ultrasound needle biopsy with and without aspiration.. Chest. 2012. DOI: 10.1378/chest.11-0692.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.