Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the accuracy of measurement of II degree furcation involvements in molars of dry mandibles by cone-beam computed tomography (CBCT).

METHODS

Twenty molars with II degree furcation involvements in dry mandibles were examined directly and measured by CBCT. Eight parameters were selected to describe the exact appearance of each II degree furcation involvements, including vertical defect dimensions, horizontal defect dimensions and furcation entrance dimensions. The results were compared with the corresponding data obtained by probing and periapical radiograph.

RESULTS

All furcation involvements could be correctly classified by CBCT. For 5 of 8 parameters, no significant difference was found between the data obtained by CBCT and probing measurements (P>0.05). The distances from furcation entrance to alveolar crest, to bottom of bone pocket, and to the deepest site of horizontal bone defect measured by CBCT were less than those probed directly (P<0.05), but the differences were less than 0.5 mm (0.21, 0.24, 0.35 mm, respectively). The localization of furcation entrance may cause the differences. Two out of 20 furcation involvements could not be detected on periapical radiographs, and only 2 of 8 parameters could be measured on periapical radiographs.

CONCLUSION

CBCT could provide precise and detailed 3D images of II degree furcation involvements in vitro.

Для цитирования: Zhong Jin-sheng, Ou-Yang Xiang-ying, Liu Deng-gao, Cao Cai-fang. [Evaluation of the in vitro quantitative measurement of II degree furcation involvements in mandibular molars by cone-beam computed tomography].. Beijing da xue xue bao. Yi xue ban = Journal of Peking University. Health sciences. 2010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.