m+Medelevator.RU
← Поиск публикаций
Microscopy research and technique · 2026

Scanning Electron Microscopic Evaluation of Indocyanine Green-Loaded Cerium Oxide Nanoparticle-Mediated Photodynamic Therapy and Potassium Titanyl Phosphate Laser as Post-Space Disinfectant: Effects on Smear Layer Removal and Bond Strength.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Alkhudhairy Fahad

Аннотация

This study evaluated the efficacy of novel post space disinfection protocols-indocyanine green-loaded cerium oxide nanoparticle-mediated photodynamic therapy (ICG-CeO2NPs-PDT), sodium hypochlorite (NaOCl), and potassium titanyl phosphate (KTP) laser irradiation-combined with ethylenediaminetetraacetic acid (EDTA) chelation on smear layer (SL) removal and push-out bond strength (PBS) of glass fiber posts (GFP) to root canal dentin. Forty-eight extracted human premolars underwent standardized endodontic treatment and post-space preparation. Specimens were randomly allocated to four groups (n = 12): Group 1 (saline + EDTA control), Group 2 (2.5% NaOCl + EDTA), Group 3 (KTP laser + EDTA), and Group 4 (ICG-CeO2NPs-PDT + EDTA). SL removal was quantified using scanning electron microscopy with a four-point scoring system. Following GFP cementation and thermocycling (10,000 cycles), PBS was measured at cervical, middle, and apical regions. Failure modes were classified as adhesive, cohesive, or mixed. Data were analyzed using one-way ANOVA and Tukey's post hoc test (α = 0.05). Groups 2 and 4 demonstrated significantly superior SL removal (scores 1.12-2.45 and 1.17-2.20, respectively) compared to Groups 1 and 3 (3.31-3.99 and 3.40-3.99, p < 0.05). Correspondingly, Groups 2 and 4 achieved 40%-60% higher push-out bond strength (6.71-7.88 MPa and 7.02-8.45 MPa) versus Groups 1 and 3 (4.51-5.27 MPa and 4.73-5.48 MPa, p < 0.05). Groups 2 and 4 exhibited predominantly cohesive failures (50%-80%), while Groups 1 and 3 showed adhesive failures (60%-90%). ICG-CeO2NPs-PDT demonstrates efficacy equivalent to conventional NaOCl-EDTA irrigation for optimizing glass fiber post adhesion, outperforming KTP laser and saline protocols, warranting clinical evaluation.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты