DOI 10.1111/dom.70355

Медицинская библиотека · Diabetes, obesity & metabolism · 2025

Impact of stepwise diabetes technology advances in older adults with type 1 diabetes: A systematic review and meta-analysis of randomised trials.

Lei Mengyun, Zhou Yongwen, Ni Ying, Lin Zhiqin, Lin Qiongyan, Ling Ping, Yang Daizhi, Xu Wen, Deng Hongrong, Yan Jinhua

СтатьяСистематический обзорМетаанализПеревод пока не подготовлен

Аннотация

OBJECTIVES

To evaluate the efficacy and safety of advancing to higher levels of diabetes technology in older adults with type 1 diabetes (T1D).

METHODS

Web of Science, PubMed, Cochrane Library, and SCOPUS were searched. Inclusion criteria were randomised controlled trials (RCTs); aged ≥60 years with T1D. Interventions were pre-specified into two domain comparisons: (1) Higher-level insulin delivery (defined as automated insulin delivery, AID) versus lower-level insulin delivery (comprising sensor-augmented pumps and predictive low-glucose suspend); and (2) Higher-level glucose monitoring (defined as continuous glucose monitoring, CGM) versus lower-level glucose monitoring (self-monitoring of blood glucose). Co-primary efficacy outcomes were time-below-range of <3.9 mmol/L(TBR3.9) and time-in-range of 3.9-10.0 mmol/L (TIR). Safety outcomes were episodes of diabetic ketoacidosis (DKA) and severe hypoglycemia (SH).

RESULTS

Five RCTs (comprising six comparisons) with 482 participants were included. Three trials enrolled participants aged ≥60 years, and two trials enrolled those aged ≥65 years. Three crossover trials contributed to the AID comparison, and two parallel to the CGM comparison. The mean age was 69.2 years, with a mean T1D duration of 36.1 years. In the pooled analysis, higher-level technologies significantly increased TIR (MD = +7.90%, 95% CI: 7.09 to 8.72, p <0.001) and reduced TBR3.9 (MD = -0.62%, 95% CI: -1.02 to -0.22, p = 0.002). Benefits were also observed for TBR <3.0 mmol/L, time-above-range >10.0 and >13.9 mmol/L, HbA1c, and glycemic variability (all p <0.05). Critically, SH risk was markedly lower with higher-level technologies (Peto OR = 0.16, 95% CI: 0.06 to 0.41, p <0.001; number-needed-to-treat = 20), without a significant increase in DKA risk (Peto OR = 3.72, 95% CI: 0.75 to 18.49, p = 0.11).

CONCLUSIONS

Advancing to higher-level technologies for glucose monitoring and insulin delivery significantly and safely improve glycemic control in older adults with T1D. Physiological age alone should not be a primary barrier to prescribing these technologies, particularly for carefully selected older adults.

Для цитирования: Lei Mengyun, Zhou Yongwen, Ni Ying, Lin Zhiqin, Lin Qiongyan, Ling Ping, Yang Daizhi, Xu Wen, Deng Hongrong, Yan Jinhua. Impact of stepwise diabetes technology advances in older adults with type 1 diabetes: A systematic review and meta-analysis of randomised trials.. Diabetes, obesity & metabolism. 2025. DOI: 10.1111/dom.70355.