Аннотация

STUDY

OBJECTIVE

Electroconvulsive therapy (ECT) has been shown to be highly effective in patients suffering from treatment-resistant depression. ECT procedure is performed under general anesthesia but the impact of anesthesia depth on seizure characteristics and clinical outcome remains unclear. We aimed to study the effects of BIS monitoring on electric and clinical response to ECT treatment.

DESIGN

Meta-analysis searching PubMed, Web of Science, Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, EMBASE, PsycINFO database, and Google Scholar.

PATIENTS/INTERVENTIONS: Studies comparing different BIS levels during ECT.

MEASUREMENT: The primary outcome measured the electrical seizure duration. Secondary outcomes measured the clinical seizure duration, and correlation between pre-ictal BIS level and awakening time. Difference in means (MD) was used for effect size.

MAIN

RESULTS

Among 38 eligible studies, 7 were analyzed including 260 patients, aged from 16 to 80 years old, benefiting from 1283 ECT sessions. Higher BIS levels were associated with longer electric seizures duration (correlation 0.61, 95% CI [0.39-0.75], 7 studies) and longer motor seizures duration (correlation 0.72, 95% CI [0.29-0.91], 6 studies).

CONCLUSIONS

High values of pre-ictal BIS are associated with improved seizure duration. The usefulness of systematic BIS monitoring during all ECT procedures should be further studied to better identify adequate BIS levels according to patient's characteristics.

Для цитирования: Guerrier Gilles, Gianni Marc-Antoine. The effectiveness of BIS monitoring during electro-convulsive therapy: A systematic review and meta-analysis.. Journal of clinical anesthesia. 2019. DOI: 10.1016/j.jclinane.2019.05.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.