Tremolada Giovanni, Hazenfield Kurt M, Smeak Daniel D

Аннотация

OBJECTIVE: To evaluate holding security of 4 friction knots created with various monofilament and multifilament sutures in a vascular ligation model.

SAMPLE: 280 friction knot constructs.

PROCEDURES: 10 friction knots of 4 types (surgeon's throw, Miller knot, Ashley modification of the Miller knot, and strangle knot) created with 2-0 monofilament (polyglyconate, polydioxanone, poliglecaprone-25, and glycomer-631) and braided multifilament (silk, lactomer, and polyglactin-910) sutures were separately tied on a mock pedicle and pressure tested to the point of leakage. Linear regression analysis was performed to compare leakage pressures among suture materials (within friction knot type) and among knot types (within suture material).

RESULTS: Mean leakage pressure of surgeon's throws was significantly lower than that of all other knots tested, regardless of the suture material used. All the other knots had mean leakage pressures considered supraphysiological. Significant differences in mean leakage pressure were detected between various friction knots tied with the same type of suture and various suture types used to create a given knot. Variability in leakage pressure among knots other than the surgeon's throw was greatest for poliglecaprone-25 and lowest for polydioxanone.

CONCLUSIONS AND CLINICAL RELEVANCE: Most differences in knot security, although statistically significant, may not have been clinically relevant. However, results of these in vitro tests suggested the surgeon's throw should be avoided as a first throw for pedicle ligation and that poliglecaprone-25 may be more prone to friction knot slippage than the other suture materials evaluated.