m+Medelevator.RU
← Поиск публикаций
Veterinary surgery : VS · 2020

Effect of partial vs complete circumferential epitendinous suture placement on the biomechanical properties and gap formation of canine cadaveric tendons.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Duffy Daniel J, Chang Yi-Jen, Fisher Matthew B, Moore George E

Аннотация

OBJECTIVE: To determine the effect of partial vs complete circumferential epitendinous suture (ES) placement in addition to a core suture on the biomechanical strength and gapping characteristics of repaired canine tendinous constructs.

STUDY DESIGN: Ex vivo, biomechanical study.

SAMPLE POPULATION: Thirty-six canine superficial digital flexor tendons.

METHODS: Superficial digital flexor tendons were randomly assigned to three groups (n = 12), sharply transected and repaired with a core locking-loop suture with Group 1 a partial circumferential ES, 180° on the palmar side; Group 2 a complete circumferential ES, 360° and double knotting technique; or Group 3 a complete circumferential ES, 360° and single knotting technique. After preloading, constructs were distracted to monotonic failure. Failure mode, gap formation, yield, peak, and failure forces were analyzed.

RESULTS: Mean yield (group 1 = 68.6 N, group 2 = 106.5 N, group 3 = 114 N, P < .013), peak (group 1 = 92.8 N, group 2 = 134.6 N, group 3 = 147.3 N; P < .001), and failure (group 1 = 88.7 N, group 2 = 133.0 N, group 3 = 145.5 N, P < .001) loads differed between groups. No difference in yield (P = .874), peak (P = .434), or failure load (P = .434) was detected between complete circumferential ES groups. Force to create 1-mm (P < .001) and 3-mm (P < .038) gap formation was greater in specimens with complete vs partial circumferential ES placement. Complete circumferential ES repairs failed primarily by suture pull-through compared with suture breakage in most partial circumferential ES constructs.

CONCLUSION: Addition of a complete circumferential ES with a single or double knotting technique increased the biomechanical strength of normal tendon repairs while reducing gap formation compared with partial ES placement alone.

CLINICAL SIGNIFICANCE: Complete circumferential ES is recommended over partial ES placement.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты