m+Medelevator.RU
← Поиск публикаций
Gastroenterology research and practice · 2021

Diagnostic Accuracy of EndoFaster® and Narrow-Band Imaging Endoscopy in Patients with Impaired Gastric Acid Secretion: A Real-Time Prospective Study.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Cazzato M, Esposito G, Galli G, Pilozzi E, Lahner E, Corleto V D, Zullo A, Di Giulio E, Annibale B

Аннотация

BACKGROUND: EndoFaster® analyzes gastric juice in real time during gastroscopy allowing the detection of hypo-achlorhydric conditions, like corpus atrophic gastritis. Narrow-band imaging (NBI) endoscopy allows to accurately detect and perform target biopsies in areas of intestinal metaplasia, a histological change often associated to corpus atrophic gastritis.

AIMS: To compare the diagnostic accuracy of EndoFaster® with histological evaluation for corpus atrophic gastritis through high-resolution (HR) NBI targeted biopsies.

METHODS: Prospective study on consecutive adult patients undergoing gastroscopy between April and November 2018. Patients in therapy with proton pump inhibitors, previous gastric surgery, and/or known gastric neoplasia were excluded. At the beginning of gastroscopy, gastric juice was aspirated and analyzed by EndoFaster® in 15 seconds. Endoscopists were blinded to the report of EndoFaster®. Evaluation of gastric mucosa in HR-white light was firstly performed, then with HR-NBI allowing to perform targeted biopsies on areas suspected for intestinal metaplasia; otherwise, biopsies were performed according to the updated Sydney System protocol and sent for histopathological evaluation.

RESULTS: Overall, 124 patients were included [64% F; 56 (18-85) years]. Corpus atrophic gastritis was present in 41.9% of patients. EndoFaster® showed an accuracy for corpus atrophic gastritis diagnosis, compared to histopathological evaluation as gold standard, of 87.1% and a sensitivity, specificity, PPV, and NPV of 78.8%, 93.1%, 89.1%, and 85.9%, respectively. pH showed a positive correlation with the severity score of atrophy (r = 0.67, 95% CI: 0.73-0.81, and p < 0.0001). EndoFaster® allowed to diagnose corpus atrophic gastritis in 3.7% of patients negative to NBI (corpus atrophic gastritis without intestinal metaplasia).

CONCLUSION: EndoFaster® seems a promising tool to diagnose corpus atrophic gastritis. The evaluation of hypo-achlorhydria during gastroscopy can address bioptic sampling in corpus atrophic gastritis patients without intestinal metaplasia.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты