Медицинская библиотека · Journal of the American College of Cardiology · 2011

Hemodynamic and clinical impact of prosthesis-patient mismatch after transcatheter aortic valve implantation.

Ewe See Hooi, Muratori Manuela, Delgado Victoria, Pepi Mauro, Tamborini Gloria, Fusini Laura, Klautz Robert J M, Gripari Paola, Bax Jeroen J, Fusari Melissa, Schalij Martin J, Marsan Nina Ajmone

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study examined the mid-term hemodynamic and clinical impact of prosthesis-patient mismatch (PPM) in patients undergoing transcatheter aortic valve implantation (TAVI) with balloon-expandable valves.

BACKGROUND

PPM can be observed after aortic valve surgery. However, little is known about the incidence of PPM in patients undergoing TAVI.

METHODS

Echocardiography and clinical assessment were performed in 165 patients at baseline, before hospital discharge, and at 6 months after TAVI. PPM was defined as an indexed effective orifice area ≤0.85 cm(2)/m(2).

RESULTS

Thirty patients (18.2%) showed PPM before hospital discharge. At baseline, patients with PPM had a larger body surface area (1.84 ± 0.18 m(2) vs. 1.73 ± 0.18 m(2), p = 0.003) and a greater severity of aortic stenosis (indexed valve area 0.35 ± 0.09 cm(2)/m(2) vs. 0.40 ± 0.10 cm(2)/m(2), p = 0.005) than patients without PPM. Patients with PPM demonstrated a slower and smaller reduction in mean transaortic gradient, limited left ventricular (LV) mass regression, and left atrial volume reduction over 6 months compared with patients without PPM. LV filling pressure, measured by E/e', tended to remain elevated in patients with PPM. Importantly, a higher proportion of patients with PPM did not improve in New York Heart Association functional class compared with patients without PPM (36.7% vs. 1.5%, p < 0.001), although major adverse valve-related and cardiovascular events did not differ between the 2 groups.

CONCLUSIONS

PPM may be observed after TAVI and when present may be accompanied by less favorable changes in transvalvular hemodynamics, limited LV mass regression, persistent elevated LV filling pressure, and less improvement in clinical functional status.

Для цитирования: Ewe See Hooi, Muratori Manuela, Delgado Victoria, Pepi Mauro, Tamborini Gloria, Fusini Laura, Klautz Robert J M, Gripari Paola, Bax Jeroen J, Fusari Melissa, Schalij Martin J, Marsan Nina Ajmone. Hemodynamic and clinical impact of prosthesis-patient mismatch after transcatheter aortic valve implantation.. Journal of the American College of Cardiology. 2011. DOI: 10.1016/j.jacc.2011.08.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.