Late restenosis following sirolimus-eluting stent implantation.

Kuriyama Nehiro, Kobayashi Yoshio, Nakama Tatsuya, Mine Daigo, Nishihira Kensaku, Shimomura Mitsuhiro, Nomura Katsumasa, Ashikaga Keiichi, Matsuyama Akihiko, Shibata Yoshisato

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

This serial angiographic study evaluated the incidence and predictors of late restenosis after sirolimus-eluting stent (SES) implantation.

BACKGROUND

Previous studies showed late restenosis (i.e., late catch-up phenomenon) after implantation of 7-hexanoyltaxol-eluting stents and nonpolymeric, paclitaxel-eluting stents.

METHODS

Between August 2004 and December 2006, SES implantation was performed in 1,393 patients with 2,008 lesions, in whom 8-month and 2-year follow-up coronary angiography were planned.

RESULTS

Of 2,008 lesions, 1,659 (83%) underwent 8-month follow-up angiography (8.3 ± 2.2 months). Restenosis was observed in 122 lesions (7.4%). Coronary angiography 2 years (1.9 ± 0.4 years) after SES deployment was performed in 1,168 lesions (74% of lesions without restenosis at 8-month follow-up angiography). Late restenosis was observed in 83 lesions (7.1%). There was significant decrease in minimum luminal diameter (MLD) between 8-month and 2-year follow-up (2.56 ± 0.56 mm vs. 2.35 ± 0.71 mm, p < 0.001). Multivariate analysis showed in-stent restenosis before SES implantation and MLD at 8-month follow-up as independent predictors of late restenosis.

CONCLUSIONS

Between 8-month and 2-year follow-up after SES implantation, MLD decreases, which results in late restenosis in some lesions. In-stent restenosis before SES implantation and MLD at 8-month follow-up are independent predictors of late restenosis.

Для цитирования: Kuriyama Nehiro, Kobayashi Yoshio, Nakama Tatsuya, Mine Daigo, Nishihira Kensaku, Shimomura Mitsuhiro, Nomura Katsumasa, Ashikaga Keiichi, Matsuyama Akihiko, Shibata Yoshisato. Late restenosis following sirolimus-eluting stent implantation.. JACC. Cardiovascular interventions. 2011. DOI: 10.1016/j.jcin.2010.09.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.