Медицинская библиотека · European journal of gastroenterology & hepatology · 2016

Impact of demographic and clinical parameters on video capsule transit time.

Niv Eva, Pinchasovich Hadassa, Yanai Henit

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Small bowel (SB) capsule endoscopy (CE) studies provide data on both gastric and SB transit times (GTT and SBTT, respectively).

AIMS: This study aimed to evaluate the influence of demographic and clinical parameters on the GTT and SBTT. Transit times for two generations of capsules (Pillcam SB2 and SB3) were also compared.

METHODS

Consecutive adult patients undergoing CE were included. GTT, SBTT, and cecum arrival rates were calculated and correlated to demographics and clinical characteristics.

RESULTS

A total of 332 CE studies were analyzed. Neither GTT nor SBTT were impacted by age or sex. SBTT was prolonged in newly diagnosed Crohn's disease (CD) patients compared with all other patients (303.1±90.3 vs. 243.6±83.6 min, P=0.02 for SB2, 267.8±63 vs. 228.6±72.3, P=0.01 for SB3, respectively). Moreover, CD patients had higher incomplete study rates compared with patients with all other diagnoses (29.4 vs. 7.3%, respectively, P=0.0116) in the SB2 subgroup. Higher cecum arrival rates were achieved by the SB3 capsule compared with SB2 (97 vs. 91%, P=0.04). Patients with prolonged gastric time or patients with incomplete studies had similar demographic and clinical characteristics as others.

CONCLUSION

Age and sex apparently do not influence intestinal kinetics. Newly diagnosed CD patients have relatively prolonged SBTTs. Demographic and clinical parameters cannot predict prolonged GTT or cecum nonarrival.

Для цитирования: Niv Eva, Pinchasovich Hadassa, Yanai Henit. Impact of demographic and clinical parameters on video capsule transit time.. European journal of gastroenterology & hepatology. 2016. DOI: 10.1097/meg.0000000000000684.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.