DOI 10.1016/s0828-282x(10)70466-9

Медицинская библиотека · The Canadian journal of cardiology · 2010

Patient-prosthesis mismatch in the mitral position affects midterm survival and functional status.

Bouchard Denis, Vanden Eynden Frédéric, Demers Philippe, Perrault Louis P, Carrier Michel, Cartier Raymond, Basmadjian Arsène J, Pellerin Michel

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The definition and incidence of patient-prosthesis mismatch (PPM) in the mitral position are unclear.

OBJECTIVES

To determine the impact of PPM on late survival and functional status after mitral valve replacement with a mechanical valve.

METHODS

Between 1992 and 2005, 714 patients (mean [± SD] age 60±10 years) underwent valve replacement with either St Jude (St Jude Medical Inc, USA) (n=295) or Carbomedics (Sulzer Carbomedics Inc, USA) (n=419) valves. There were 52 concomitant procedures (50 tricuspid annuloplasties, 25 foramen oval closures and 20 radiofrequency mazes). The mean clinical follow-up period was 4.4±3.3 years. The severity of PPM was established with cut-off values for an indexed effective orifice area (EOAi) of lower than 1.2 cm(2)⁄m(2), lower than 1.3 cm(2)⁄m(2) and lower than 1.4 cm(2)⁄m(2). Parametric and nonparametric tests were used to determine predictors of outcome.

RESULTS

The prevalence of PPM was 3.7%, 10.1% and 23.5% when considering values of lower than 1.2 cm(2)⁄m(2), lower than 1.3 cm(2)⁄m(2) and lower than 1.4 cm(2)⁄m(2), respectively. When considering functional improvement, patients with an EOAi of 1.4 cm(2)⁄m(2) or greater had a better outcome than those with an EOAi of lower than 1.4 cm(2)⁄m(2) (OR 1.98; P=0.03). When building a Cox-proportional hazard model, PPM with an EOAi of less than 1.3 cm(2)⁄m(2) was an independent predictive factor for midterm survival (HR 2.24, P=0.007). Other factors affecting survival were age (HR 1.039), preoperative New York Heart Association class (HR 1.96) and body surface area (HR 0.31).

CONCLUSIONS

In a large cohort of patients undergoing mitral valve replacement with mechanical prostheses, PPM defined as an EOAi of lower than 1.3 cm(2)⁄m(2) significantly decreased midterm survival. This level of PPM was observed in 10.2% of patients. Patients with an EOAi of 1.4 cm(2)⁄m(2) or greater had greater improvement of their functional status.

Для цитирования: Bouchard Denis, Vanden Eynden Frédéric, Demers Philippe, Perrault Louis P, Carrier Michel, Cartier Raymond, Basmadjian Arsène J, Pellerin Michel. Patient-prosthesis mismatch in the mitral position affects midterm survival and functional status.. The Canadian journal of cardiology. 2010. DOI: 10.1016/s0828-282x(10)70466-9.

Предметные рубрики MeSH