MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/bjs/znag090

Медицинская библиотека · The British journal of surgery · 2026

European Society of Endocrine Surgeons (ESES) consensus statement on standardization and research requirements for intraoperative nerve monitoring in endocrine surgery.

Brauckhoff Katrin, Dukaczewska Agata, Princi Pietro, Schneider Rick, Van Slycke Sam, Yaliman Selen S, Staubitz-Vernazza Julia I, Tolley Neil S, Vamvakidis Kyriakos, Zorbas Ilias A, Musholt Thomas J

Consensus StatementСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Intraoperative nerve monitoring (IONM) is widely used in endocrine surgery, yet substantial heterogeneity exists in its documentation, interpretation, and reporting. This limits comparability across studies and hampers the evaluation of clinical outcomes.

METHODS

A consensus process was conducted by the European Society of Endocrine Surgeons (ESES), combining a systematic literature review, analysis of Eurocrine® registry data, a survey among ESES members, and a structured Delphi consensus process.

RESULTS

Considerable variability was identified in monitoring techniques, signal interpretation, and outcome reporting. Key areas requiring standardization include the definition of loss of signal, documentation of neuromonitoring parameters, reporting of technical settings, and objective assessment of vocal cord function. Based on these findings, a set of consensus statements was developed to define minimum requirements for IONM research and reporting.

CONCLUSION

This consensus statement provides a structured framework to improve standardization, data quality, and comparability in IONM research. Adoption of the recommendations may facilitate more robust evaluation of clinical outcomes and support future evidence generation in endocrine surgery.

Для цитирования: Brauckhoff Katrin, Dukaczewska Agata, Princi Pietro, Schneider Rick, Van Slycke Sam, Yaliman Selen S, Staubitz-Vernazza Julia I, Tolley Neil S, Vamvakidis Kyriakos, Zorbas Ilias A, Musholt Thomas J. European Society of Endocrine Surgeons (ESES) consensus statement on standardization and research requirements for intraoperative nerve monitoring in endocrine surgery.. The British journal of surgery. 2026. DOI: 10.1093/bjs/znag090.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.