MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-021-82359-1

Медицинская библиотека · Scientific reports · 2021

Preclinical assessment of a modified Occlutech left atrial appendage closure device in a porcine model.

Reinthaler Markus, Grosshauser Johannes, Schmidt Tanja, Unger Juliane, Morgan Ross, Zimmermann Friederike, Hartung Johannes, Seppelt Claudio, Meteva Denitsa, Haider Wolfram, Landmesser Ulf, Skurk Carsten

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Left atrial appendage (LAA) closure is being developed as an alternative for stroke prevention in patients with atrial fibrillation that cannot tolerate long-term oral anticoagulation. To assess the feasibility, safety, and performance of a novel modified Occlutech LAA closure device in a preclinical porcine model, the modified Occlutech modified Occlutech Plus LAA closure device was implanted in 12 female pigs (25-39 kg body weight) under fluoroscopic and transesophageal echocardiography (TEE) guidance. Procedural and technical success, as well as safety of LAA closure, were evaluated peri-procedurally and after 4, 8, and 12 weeks. Moreover, after 4, 8 and, 12 weeks animals were sacrificed for pathological analysis (e.g., thrombus formation, device ingrowth, endothelialization, and inflammation). All LAA closure devices were successfully implanted. On follow-up, no serious adverse events such as device-associated thrombus or translocalization/embolization were observed. A clinically non-significant pericarditis was observed in 4 animals at the time of autopsy. Endothelialization of the device was visible after 4 weeks, advanced after 8 weeks and completed after 12 weeks. Immunohistochemistry showed low amounts of inflammatory infiltration on the edges of the device. The results of this study indicate that implantation of a modified Occlutech LAA closure device is feasible with rapid endothelialization and low inflammatory infiltration in a porcine model. Human data are needed to further characterize safety and efficacy.

Для цитирования: Reinthaler Markus, Grosshauser Johannes, Schmidt Tanja, Unger Juliane, Morgan Ross, Zimmermann Friederike, Hartung Johannes, Seppelt Claudio, Meteva Denitsa, Haider Wolfram, Landmesser Ulf, Skurk Carsten. Preclinical assessment of a modified Occlutech left atrial appendage closure device in a porcine model.. Scientific reports. 2021. DOI: 10.1038/s41598-021-82359-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.